NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 117 pages

Quality Assurance Plan, Ambient Air Monitoring Program

Machine-extracted title · confidence 60%

Draft QA Plan for ambient air monitoring at 130 Liberty Street deconstruction project, Aug 2005.

NYC-WTC_000449648–000449764
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

Z ■< Z ■<

o Ambient Air Monitoring Program Section No. 8 o co g Quality Assurance Project Plan Revision No.: 0

I o 130 Liberty Street - NY, NY Date: August 2005 “0 o Lower Manliattan Development Corporation Page 40 of 116 c o CT o o' CD "0 O> o CO co Table 8-2. Measurement Performance Criteria Table - Metals by ICP/MS 03 QC Sample or Activity Frequency Measurement Performance Criteria Corrective Action DQI O o Field Duplicates 1/week *RPD < 40 when positive results for both Assess laboratory precision, qualify Precision-Overall o c samples are > 5x QL data, and/or resample data. 3 *No situation where one result is detected o 3 at > 5x QL and other result is not detected Laboratory Duplicates l/prep batch RPD < 20 if results are > 5x QL Qualify data. Precision-Laboratory Laboratory Control Sample l/prep batch Percent recoveries 75-125% Determine cause of problem, Accuracy/Bias reanalyze, and/or qualify data. Laboratory Control Sample l/prep batch Percent recoveries 75-125%; RPD < 20 Determine cause of problem, Accuracy/Bias and Dupheate reanalyze, and/or qualify data. Precision Serial Dilution Analysis 1/batch + 10% of original result Qualify data. Accuracy/Bias Interference Check Sample 1/8 hours Percent recoveries 80-120% Recalibrate and reanalyze and/or Accuracy/Bias qualify data. Calibration Blanks 1/10 samples Absolute value of target metal must be Reclean, restest, reanalyze, and/or Accuracy/Bias - <QL qualify data. Contamination Preparation Blanks l/prep batch Absolute value of target metal must be Reclean, restest, reanalyze, and/or Accuracy/Bias - <QL qualify data. Contamination Field/Trip Blanks 1/day Absolute value of target metal must be Reclean, restest, reanalyze, and/or Accuracy/Bias - <QL qualify data. Contamination Quartz Fiber Filter Media 1/batch Absolute value of target metal must be Obtain new lot of media. Accuracy/Bias - Cleaning Verification Check <QL Contamination Internal Standards Every sample, Samples: 30-130% of IS calibration blank Dilute sample 5x, add IS and Accuracy/Bias blank, QC Calibration Standards: 80-120% of IS in reanalyze, and/or qualify data. calibration blank Instrument Tune Daily, prior to Mass resolution < 1.0 amu at 10% peak Retune instrument, repeat tune Accuracy/Bias calibration and height and mass calibration + 0.1 amu solution and analysis. sample analysis from the expected value Data Completeness Check NA Field 80%, Laboratory 95% NA Data Completeness o H k; I to

s O o o I o o co to co L2005-346 Rev. 1 co co co

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000449688Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000428324

Draft QA project plan for Ambient Air Monitoring Program at 130 Liberty Street deconstruction (Aug 2005).

Similar indexed content

NYC-WTC_000441561

Quality Assurance Project Plan for ambient air monitoring at 130 Liberty Street deconstruction, Aug 2005.

Similar indexed content

NYC-WTC_000427221

Draft QA Project Plan for ambient air monitoring at 130 Liberty Street deconstruction, TRC scope, Aug 2005.

Similar indexed content

NYC-WTC_000444248

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

NYC-WTC_000447891

QA plan for ambient air monitoring at 130 Liberty Street, Sept 7, 2005.

Similar indexed content

Compare copies and versions →