Quality Assurance Plan, Ambient Air Monitoring

Machine-extracted title · confidence 46%

QA plan for ambient air monitoring at 130 Liberty Street, Sept 7, 2005.

NYC-WTC_000447891–000448022
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

Z ■< Z ■<

o Ambient Air Monitoring Program Section No. 8 o co g Quality Assurance Project Plan Revision No.: 0

I o 130 Liberty Street - NY, NY Date: September 7, 2005 “0 o Lower Manliattan Development Corporation Page 46 of 124 c o CT o o' "0 CD o Ca3 Table 8-2. Measurement Performance Criteria Table - Metals by ICP/MS 03 QC Sample or Activity Frequency Measurement Performance Criteria Corrective Action DQI O o Field Duplicates 1/week *RPD < 40 when positive results for both Assess laboratory precision, and /or Precision-Overall o c samples are > 5x QL qualify data. 3 *No situation where one result is detected o 3 at > 5x QL and other result is not detected Laboratory Duplicates l/prep batch RPD < 20 if results are > 5x QL Qualify data. Precision-Laboratory Laboratory Control Sample l/prep batch Percent recoveries 75-125% Determine cause of problem, Accuracy/Bias reanalyze, and/or qualify data. Laboratory Control Sample l/prep batch Percent recoveries 75-125%; RPD < 20 Determine cause of problem, Accuracy/Bias and Dupheate reanalyze, and/or qualify data. Precision Serial Dilution Analysis 1/batch + 10% of original result Qualify data. Accuracy/Bias Interference Check Sample 1/8 hours Percent recoveries 80-120% Recalibrate and reanalyze and/or Accuracy/Bias qualify data. Calibration Blanks 1/10 samples Absolute value of target metal must be Reclean, reanalyze, and/or qualify Accuracy/Bias - .^QL_______________________________ data. Contamination Preparation Blanks l/prep batch Absolute value of target metal must be Reclean, reanalyze, and/or qualify Accuracy/Bias - .^QL_______________________________ data. Contamination Field/Trip Blanks 1/day Absolute value of target metal must be Reclean, reanalyze, and/or qualify Accuracy/Bias - .^QL_______________________________ data. Contamination Quartz Fiber Filter Media 1/batch Absolute value of target metal must be Obtain new lot of media. Accuracy/Bias - Cleaning Verification Check <QL Contamination Internal Standards Every sample, Samples: 30-130% of IS calibration blank Dilute sample 5x, add IS and Accuracy/Bias blank, QC Calibration Standards: 80-120% of IS in reanalyze, and/or qualify data. calibration blank Instrument Tune Daily, prior to Mass resolution < 1.0 amu at 10% peak Retune instrument, repeat tune Accuracy/Bias calibration and height and mass calibration + 0.1 amu solution and analysis. sample analysis from the expected value Data Completeness Check NA Field 80%, Laboratory 95% NA Data Completeness o H k; Reanalyze: refers to reanalysis of same digestate or QC sample. I to

s O o o I o o co to

co co to

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000447937Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000449908

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 7, 2005.

Similar indexed content

NYC-WTC_000447031

QA plan document for ambient air monitoring program for Liberty Street deconstruction.

Similar indexed content

NYC-WTC_000443239

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, LMDC.

Similar indexed content

NYC-WTC_000444248

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

Compare copies and versions →