NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - Rev 1 - January 27, 2006
Method TO-13A, does not collect particulate matter representative solely of potential
inhalation exposure, but provides for a total of respirable and non-respirable PAHs.
Sorbent traps containing polyurethane foam (PUF) and XAD-2® resin in a “sandwich”
configuration. The Tisch PUF high volume sorbent sampler (or performance equivalent)
located at each monitoring station will be operated at a flow rate of 200 to 300 liters per
minute with a sampling period of approximately 24 hours for a resulting total air volume
of approximately 288 ms - 432 ma. The filters and sorbent cartridges will be solvent pre
cleaned and vacuum dried by the analytical laboratory. The pre-cleaned filters and
cartridges will be stored wrapped in aluminum foil (or otherwise protected from light) in
a Ziploc bag, and over wrapped with bubble wrap until they are carefully installed on the
sampler on site. At the conclusion of each sampling period, the sample is recovered from
the sampling train by placing the filter inside the glass cartridge. The cartridge is then
wrapped with aluminum foil and it is placed back into its original shipping container,
labeled, and transported to the analytical laboratory for processing. The amount of air
sampled through the filters and cartridges will be recorded and the filter/cartridge set
placed in an appropriately labeled container and shipped to the laboratory
for analysis. Equipment and supplies utilized with this sampling approach are as follows:
• High-Volume Sampler - Tisch PUF (or performance equivalent). Capable of
pulling ambient air through the filter/sorbent cartridge at a flow rate
of approximately 200-300 1pm over a 24-hour sampling period.
• Sampling Module - Metal filter holder capable of holding a 102-mm circular
particle filter supported by a 16-mesh stainless-steel screen and attaching to a
metal cylinder capable of holding a 65-mm O.D. (60-miu I.D.) x 125-miu
borosilicate glass sorbent cartridge containing PUF and XAD-2® resin in the
“sandwich” configuration. To ensure air-tight seals, the filter holder is equipped
with inert sealing gaskets placed on either side of the filter and inert pliable
gaskets placed at either end of the glass sorbent cartridge.
• High-Volume Sampler Calibrator - Capable of providing multi-point resistance
for the high volume sampler.
• Quartz Fiber Filter - 102 mm binderless quartz microfiber filter. (Provided by
the laboratory, pre-cleaned and weighed.)
• Polyurethane Foam (PUF) Plugs - 3-inch thick sheet stock polyurethane type
(density 0.022 g/cm3). Plugs should be slightly larger in diameter than the
internal diameter of the cartridge.
• XAD-2® Resin - Used to assemble the PUF/XAD-2 “sandwich” cartridges.
Supelco (or equivalent). Pre-cleaned and assembled by the analytical laboratory.
• White Cotton Gloves - For handling the filters and cartridges.
• Sample Cartridge Shipping Containers - The analytical laboratory will provide
individually labeled containers that will be used to transport the sample cartridges
to the field location and back to the laboratory for analysis. This will include
aluminum foil wrapped around the cartridge and a glass jar large enough to hold
the cartridge.
• 0-100” Magnehelic Gage.
63
CITY_21MC100_011979803
NYC-WTC_000448147
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000448147Source: NYC Law Department, mirrored locally