NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 134 pages

Chain of custody, Greenwich/Thames Air Monitoring Plan

Machine-extracted title · confidence 50%

Title/approval sheet for Environmental Community Air Monitoring Program and Greenwich/Thames Plan.

NYC-WTC_000448085–000448218
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - Rev 1 - January 27, 2006

Method TO-13A, does not collect particulate matter representative solely of potential inhalation exposure, but provides for a total of respirable and non-respirable PAHs. Sorbent traps containing polyurethane foam (PUF) and XAD-2® resin in a “sandwich” configuration. The Tisch PUF high volume sorbent sampler (or performance equivalent) located at each monitoring station will be operated at a flow rate of 200 to 300 liters per minute with a sampling period of approximately 24 hours for a resulting total air volume of approximately 288 ms - 432 ma. The filters and sorbent cartridges will be solvent pre­ cleaned and vacuum dried by the analytical laboratory. The pre-cleaned filters and cartridges will be stored wrapped in aluminum foil (or otherwise protected from light) in a Ziploc bag, and over wrapped with bubble wrap until they are carefully installed on the sampler on site. At the conclusion of each sampling period, the sample is recovered from the sampling train by placing the filter inside the glass cartridge. The cartridge is then wrapped with aluminum foil and it is placed back into its original shipping container, labeled, and transported to the analytical laboratory for processing. The amount of air sampled through the filters and cartridges will be recorded and the filter/cartridge set placed in an appropriately labeled container and shipped to the laboratory for analysis. Equipment and supplies utilized with this sampling approach are as follows:

• High-Volume Sampler - Tisch PUF (or performance equivalent). Capable of pulling ambient air through the filter/sorbent cartridge at a flow rate of approximately 200-300 1pm over a 24-hour sampling period. • Sampling Module - Metal filter holder capable of holding a 102-mm circular particle filter supported by a 16-mesh stainless-steel screen and attaching to a metal cylinder capable of holding a 65-mm O.D. (60-miu I.D.) x 125-miu borosilicate glass sorbent cartridge containing PUF and XAD-2® resin in the “sandwich” configuration. To ensure air-tight seals, the filter holder is equipped with inert sealing gaskets placed on either side of the filter and inert pliable gaskets placed at either end of the glass sorbent cartridge. • High-Volume Sampler Calibrator - Capable of providing multi-point resistance for the high volume sampler. • Quartz Fiber Filter - 102 mm binderless quartz microfiber filter. (Provided by the laboratory, pre-cleaned and weighed.) • Polyurethane Foam (PUF) Plugs - 3-inch thick sheet stock polyurethane type (density 0.022 g/cm3). Plugs should be slightly larger in diameter than the internal diameter of the cartridge. • XAD-2® Resin - Used to assemble the PUF/XAD-2 “sandwich” cartridges. Supelco (or equivalent). Pre-cleaned and assembled by the analytical laboratory. • White Cotton Gloves - For handling the filters and cartridges. • Sample Cartridge Shipping Containers - The analytical laboratory will provide individually labeled containers that will be used to transport the sample cartridges to the field location and back to the laboratory for analysis. This will include aluminum foil wrapped around the cartridge and a glass jar large enough to hold the cartridge. • 0-100” Magnehelic Gage.

63

CITY_21MC100_011979803

NYC-WTC_000448147

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000448147Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000446145

Chain-of-custody form for Environmental Community Air Monitoring Program samples at Greenwich/Thames sites.

Similar indexed content

NYC-WTC_000446622

Part V plan for Environmental Community Air Monitoring at Greenwich/Thames sites.

Similar indexed content

NYC-WTC_000453085

Plan for Greenwich Street and Thames Street monitoring within WTC-related cleanup.

Similar indexed content

NYC-WTC_000441133

Plan for Environmental Community Air Monitoring at Greenwich/Thames sites, Nov 2005.

Similar indexed content

NYC-WTC_000444496

Plan documents for environmental community air monitoring at Greenwich/Thames street sites, Nov 2005.

Similar indexed content

Compare copies and versions →