recovered from the sampling train by placing the filter inside the glass cartridge. The
glass cartridge is then wrapped with aluminum foil and it is placed back into its original
shipping container, labeled, and transported to the analytical laboratory for
processing. Equipment and supplies utilized with this sampling approach are as follows:
• High-Volume Sampler - Tisch PUF (or equivalent), capable of pulling ambient
air through the filter/adsorbent cartridge sampling train at a flow rate of 200- 300
1pm to obtain a total sample volume of 288-432 ms over a 24-hour period. • High-
Volume Sampler Calibrator - Capable of providing multipoint resistance for the
highvolume sampler.
• Quartz Fiber Filters - 102 millimeter (102-mm) bindless quartz microfiber filter,
Whatman International Etd, QMA-4 (or equivalent), provided by the laboratory,
pre-cleaned and weighed.
• Polyurethane Foam (PUF) Plugs - 3-inch thick sheet stock polyurethane type
(density 0.022 g/cm3). Plugs should be slightly larger in diameter than the
internal diameter of the cartridge.
• Teflon® End Caps - For sample cartridge. Must fit tightly to provide an adequate
seal to prevent pre- or post- sampling exposure to other potential sources of the
target analytes.
• Glass Sample Cartridge - For sample collection. The analytical laboratory will
insert the PUF plug into the glass sample cartridge during pre-sampling
preparation. • Sample Cartridge Aluminum Shipping Containers - The analytical
laboratory will provide individually labeled containers that will be used to
transport the sample cartridges to the field location and back to the laboratory for
analysis.
• 0-100” Magnehelic Gage.
• White Cotton Gloves - For handling the filters and cartridges.
• Ice Chests - To hold samples at 4 Y' during shipment to the analytical laboratory.
10.2.6 Polychlorinated Biphenyls (PCBs)
Ambient PCB air samples will be collected in the same sample train concurrently with
the Dioxin/Furan samples referenced in Section 10.2.5. Sample collection will be
conducted using the same equipment and a double-loaded PUF filter tube for both Dioxin
and PCBs prepared by the analytical laboratory for the collection of gas and particulate
phase PCBs. Samples will be collected at a flow rate between 200 and 300 liters per
minute (1pm) with a sampling period of approximately 24 hours for a resulting total air
volume of between 288 and 482 cubic meters (ms). The PUF (Polyurethane Foam)
sampler is an air sampling system designed to trap airborne organic vapors. Analysis will
be by Compendium Method TO-4A.
10.2.7 Polycyclic Aromatic Hydrocarbons (PAHs)
PAH samples will be collected using bigb-volume air samplers fitted with non-size
selective quartz fiber filters and sorbent cartridges. This approach, as described in EPA
62