NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 134 pages

Chain of custody, Greenwich/Thames Air Monitoring Plan

Machine-extracted title · confidence 50%

Title/approval sheet for Environmental Community Air Monitoring Program and Greenwich/Thames Plan.

NYC-WTC_000448085–000448218
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - Rev 1 - January 27, 2006

recovered from the sampling train by placing the filter inside the glass cartridge. The glass cartridge is then wrapped with aluminum foil and it is placed back into its original shipping container, labeled, and transported to the analytical laboratory for processing. Equipment and supplies utilized with this sampling approach are as follows: • High-Volume Sampler - Tisch PUF (or equivalent), capable of pulling ambient air through the filter/adsorbent cartridge sampling train at a flow rate of 200- 300 1pm to obtain a total sample volume of 288-432 ms over a 24-hour period. • High- Volume Sampler Calibrator - Capable of providing multipoint resistance for the highvolume sampler. • Quartz Fiber Filters - 102 millimeter (102-mm) bindless quartz microfiber filter, Whatman International Etd, QMA-4 (or equivalent), provided by the laboratory, pre-cleaned and weighed. • Polyurethane Foam (PUF) Plugs - 3-inch thick sheet stock polyurethane type (density 0.022 g/cm3). Plugs should be slightly larger in diameter than the internal diameter of the cartridge. • Teflon® End Caps - For sample cartridge. Must fit tightly to provide an adequate seal to prevent pre- or post- sampling exposure to other potential sources of the target analytes. • Glass Sample Cartridge - For sample collection. The analytical laboratory will insert the PUF plug into the glass sample cartridge during pre-sampling preparation. • Sample Cartridge Aluminum Shipping Containers - The analytical laboratory will provide individually labeled containers that will be used to transport the sample cartridges to the field location and back to the laboratory for analysis. • 0-100” Magnehelic Gage. • White Cotton Gloves - For handling the filters and cartridges. • Ice Chests - To hold samples at 4 Y' during shipment to the analytical laboratory.

10.2.6 Polychlorinated Biphenyls (PCBs)

Ambient PCB air samples will be collected in the same sample train concurrently with the Dioxin/Furan samples referenced in Section 10.2.5. Sample collection will be conducted using the same equipment and a double-loaded PUF filter tube for both Dioxin and PCBs prepared by the analytical laboratory for the collection of gas and particulate phase PCBs. Samples will be collected at a flow rate between 200 and 300 liters per minute (1pm) with a sampling period of approximately 24 hours for a resulting total air volume of between 288 and 482 cubic meters (ms). The PUF (Polyurethane Foam) sampler is an air sampling system designed to trap airborne organic vapors. Analysis will be by Compendium Method TO-4A.

10.2.7 Polycyclic Aromatic Hydrocarbons (PAHs)

PAH samples will be collected using bigb-volume air samplers fitted with non-size selective quartz fiber filters and sorbent cartridges. This approach, as described in EPA

62

CITY_21MC100_011979802

NYC-WTC_000448146

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000448146Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000446145

Chain-of-custody form for Environmental Community Air Monitoring Program samples at Greenwich/Thames sites.

Similar indexed content

NYC-WTC_000446622

Part V plan for Environmental Community Air Monitoring at Greenwich/Thames sites.

Similar indexed content

NYC-WTC_000453085

Plan for Greenwich Street and Thames Street monitoring within WTC-related cleanup.

Similar indexed content

NYC-WTC_000441133

Plan for Environmental Community Air Monitoring at Greenwich/Thames sites, Nov 2005.

Similar indexed content

NYC-WTC_000444496

Plan documents for environmental community air monitoring at Greenwich/Thames street sites, Nov 2005.

Similar indexed content

Compare copies and versions →