NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Slreet/21-23 Thames Street
Airtek Project 05-0701 - November 4, 2005
sample disposal and the introduction of field investigation results as evidence in legal
proceedings when pertinent) must be documented. Sample chain-of-custody and
packaging procedures are summarized below. These procedures will ensure that the
samples will arrive at the laboratory with the chain-of-custody intact.
The AIRTEK Field Sampling Coordinator (or designee) is responsible for overseeing and
supervising the implementation of proper sample custody procedures in the field and up
until the samples have been transferred to a courier. The chain-of-custody procedures are
initiated in the field immediately following sample collection. The procedures consist of:
(1) preparing and attaching a unique sample label to each sample collected, (2)
completing the chain-of-custody form, and (3) preparing and packing the samples for
shipment.
• The field sampler is personally responsible for the care and custody of the
samples until they are transferred or dispatched properly. Field procedures have
been designed such that as few people as possible will handle the samples.
• All media will be identified by the use of pre-printed adhesive sample labels with
site name and location, sample locations, date/time of collection, type of
preservation, type of analysis, and sampler’s initials. The sample numbering
system is presented in Section 14.2.2 of this QAPP. Figure 12-1 provides an
example sample label. In most cases, sample labels will be generated prior to the
sampling event.
• Sample labels will be completed for each sample using waterproof ink unless
prohibited by weather conditions. For example, a logbook notation would explain
that a pencil was used to fill out the sample label because the pen would not
function in wet weather. Tf a label is lost or ruined, sample analysis will continue.
If a project action level is exceeded, further investigation will be performed.
• Samples will be transported in containers (coolers) which will maintain the
refrigeration temperature for those parameters for which refrigeration is required .
• Samples will be accompanied by a properly completed chain-of-custody form.
The sample numbers and locations will be listed on the chain-of-custody form.
When transferring the possession of samples, the individuals relinquishing and
receiving will sign, date, and note the time on the record. This record documents
the transfer of custody of samples from the sampler to another person, to a mobile
laboratory, to the permanent laboratory, or to/ffom a secure storage location.
• Chain-of-custody records are initiated by the samplers in the field. The field
portion of the custody documentation should include: (1) the project name; (2)
signatures of samplers; (3) the sample number, date and time of collection; (4)
signatures of individuals involved in sampling; (5) identification number of media
associated with each sample; and (6) if applicable, air bill or other shipping
75
CITY_21MC100_003237479
NYC-WTC_000447508
OCR can misread numbers and units. Confirm readings against the page image before using them.