NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - November 4, 2005
10.2.11 RCRA Waste Sampling
Bulk sample collection of building components for hazard classification will include the
following RCRA waste characteristic analytical procedures:
• Ignitability (RCRA waste code DOOl). American Society of Testing Materials
(ASTM) method D-93-79 or D-93-80 or D-3278-78.
• Corrosivity (RCRA waste code D002). Method 9045D or 9040C in “Test
Methods for Evaluating Solid Waste, PhysicaEChemical Methods,” EPA
Publication SW-846. NOTE: liquids may be characterized as corrosive wastes.
• Reactivity (RCRA waste code D003). Analytical methods outlined in sections
7.3.3.2 or 7.3.4.2 of “Test Methods for Evaluating Solid Waste,
Physical/Chemical Methods,” EPA Publication SW-846.
• Toxicity. The characteristics of toxicity carry the RCRA waste codes of D004
through D043. Each waste code identifies the specific chemical component for
which the waste is classified as toxic. The samples to be analyzed for the
characteristic of toxicity must be prepared using the Toxicity Characteristic
Leaching Procedures (TCLP) per Method 1311 in “Test Methods for Evaluating
Solid Waste, Physical/Chemical Methods,” EPA Publication SW-846. The
analytical method applied to the resulting leachate depends on the type of
chemical being analyzed for, as follows:
1. Mercury (D009) Method 7470A (aqueous samples) of “Methods for
Evaluating Solid Waste, Physical/Chemical Methods,” EPA Publication
SW-846Metals/inorganics other than mercury. Method 601 OB or 6020
of “ Methods for Evaluating Solid Waste, Physical/Chemical Methods,”
EPA Publication SW-846.
2. TCLP volatile organic compound (VOC) toxic constituents, Method
SW846-1311 Method 8260B;
3. TCLP semivolatile organic compound (SVOC) toxic constituents, SW846-
1311 Method 8270C;
4. TCLP pesticide and herbicide toxic constituents. Method SW846-1311
8081Aand8151A.
Building components would generally not be considered as possible RCRA characteristic
wastes except for the potential that exists due to impacts by WTC dust. The notable
exception to this would be surfaces painted with lead-based paint, which would typically
be sampled for TCLP lead analysis. The results of RCRA characteristic analyses, as well
as the material’s status as asbestos contaminated, will be used as the basis for the Waste
Profile for the particular waste stream. All RCRA Characteristic results will be compared
to 40 CFR 261 parts 21 through 23. In addition, the cyanide and sulfide reactivity results
will be compared to SW 846 Chapter 7, Characteristics Introduction and Regulatory
Definitions Interim Guidance Values.