Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - November 4, 2005
• Sample Cartridge Shipping Containers - The analytical laboratory will provide
individually labeled containers that will be used to transport the sample cartridges
to the field location and back to the laboratory for analysis. This will include
aluminum foil wrapped around the cartridge and a glass jar large enough to hold
the cartridge.
• 0-100” Magnehelic Gage.
• Ice Chests - To hold samples at 4°C during shipment to the analytical laboratory.
10.2.8 Mercury (Total)
An iodated carbon trap is used to collect total mercury (particulate associated and vapor).
The samples are then analyzed using cold vapor atomic fluorescence (CVAFS). The
carbon trap is a proven and sensitive method for detecting trace ambient levels of
atmospheric mercury. To collect the mercury sample, a personal sampling pump will be
attached to the carbon trap and set at a flow rate of approximately 0.4 liters per minute for
24 hours for a resulting total air volume of approximately 0.6 rro. There will be either be
an arrow on the tube indicating the direction of the air flow or the technician should be
aware that air needs to flow into the section of the tube with the larger portion of sorbent.
Prior to collection, the end plugs of the carbon traps will be removed while wearing clean
gloves and placed into the bag in which the tube was received. At the completion of
sampling, these plugs will be placed back on the carbon traps while wearing clean gloves.
It is essential that these plugs be kept clean during the sampling process. Equipment and
supplies utilized with this sampling approach are as follows:
• Personal Sampling Pump - The pump used to draw the air through the iodated
carbon trap.
• Flow Measurement Device - A device such as a rotometer, bubble meter, or gas
volume displacement-measuring device such as a “DryCal” flow meter. This
device should have a calibration traceable to a NIST certification.
• lodated Carbon Trap - The carbon trap provided by the subcontracted laboratory
that is used to absorb the mercury from the air that is passed through it.
10.2.9 PMio
PMio will be determined by two separate methods. At each location, PMio will be
determined by a non-reference method utilizing Met One’s E-BAM Mass Monitor, which
is a real-time monitor. A Rupprecht & Patshinck TEOM Series 1400a monitor measuring
the ambient particulate mass concentration of PM-10 in real time will be operated at one
location each day. The TEOM sampler will be collocated along side the real-time PMio
monitors as a QA check. The TEOM sampler will rotate on a bi-weekly basis through all
real-time PMio monitor locations for the duration of the monitoring program.
10.2.9.1 PMio-Reference Method via TEOM 1400a
Rupprecht & Patshinck TEOM Series 1400a monitor will measure the ambient
61
CITY_21MC100_003237465
NYC-WTC_000447494