Part V - Quality Assurance Project Plan
133-135 Greenwich Slreet/21-23 Thames Street
Airtek Project 05-0701 - November 4, 2005
prior to the start of each sampling event. The air sampler draws up to 400 liters through
the filter during each sampling event. The MCE filters will be analyzed for ten (10)
metals: antimony, barium, beryllium, cadmium, chromium, copper, lead, manganese,
nickel, and zinc. Equipment and supplies utilized with this sampling approach are as
follows:
• Eilters -37mm 0.8um mixed cellulose ester filters.
• Area Sampling Pump 2 to 15 1pm.
• High-flow Rotometer 2-20 1pm.
10.2.2 Mercury (Gas)
Real-time monitoring for mercury will be performed utilizing an OhioLumex RA 915+
direct read instrument. The OhioEumex RA 915+ is a factory-calibrated instrument based
on a cold vapor Zeeman atomic absorption analytical process that reduces interference
from molecular absorption bands and scattered spectra. A mercury electrodeless
discharge lamp (EDE) is used as the radiation source. The sampling system consists of a
sample pump operating at 20 E/min. and a multi-path sample cell with an effective path
length of 10 meters. Equipment and supplies utilized with this sampling approach are as
follows:
• OhioEumex RA-915+ Mercury Analyzer - A portable, self-contained field
mercury analyzer used to make real time mercury vapor determinations.
• Air Intake Hose with Pre-Filter - The sampling line and first pass filter used to
remove particulate from the sample gas.
• Absorption and Dust Filters - Spare filters used as replacements for the internal
particulate and mercury absorbing filters in the instrument.
10.2.3 Asbestos
Asbestos sample collection will be performed in accordance with NIOSH Method 7402 -
Asbestos by TEM following the recommendations for personal sampling. Samples will
be collected at a rate of six liters per minute (6 1pm) for a minimum of eight (8) hours for
a resulting total volume of approximately 2.88 ms. To ensure optimum accuracy, the
sampling rate will be adjusted, as needed, to produce a fiber density of 100 to 1,300
libers mni '. Pump flow rates of each area sampling pump, with a representative sampler
in line, will be measured before and after sample collection. The pump will be run for 10
minutes prior to checking the flow rate. A suitable rotometer (or bubble meter) will be
connected to the filter inlet, the flow screw adjusted to the desired sampling value, and
the flow rate observed on the rotometer (or bubble meter) will be verified as constant for
a minimum of 20 seconds. Plow rates will be recorded on Field Sampling Data Sheets or
an equivalent field logbook. Immediately prior to collecting a sample, the sampler will be
fastened to a location (i.e., on a tripod) near the individual’s breathing zone, the top cover
of the filter cassette cowl extension (“open face”) will be removed and positioned “face
down” in the sampler. The joint between the extender and monitor body will be wrapped
with tape to hold the cassette securely in place and to provide a surface to identify the
cassette. At the end of the sampling period, the top cover and small end caps are replaced.