NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Streel/21-23 Thames Street
Airtek Project 05-0701 - Rev 1 - February 1, 2006
FIGURE 6-2
SAMPLE SCHEDULE
Samples Received at Lab
(24 Hours After Collected)*
24 HOURS 48 3 DAYS 5 DAYS 7 DAYS 9 DAYS 10 DAYS 12 DAYS
HOURS
Asbestos- Asbestos- Metals, PCDD/PCDF, Weekly Data Hardcopy Hardcopy Hardcopy
PCMe TEM Hg, PAH, AND Summary Asbestos Silica, PCDD,
EDD to EDD to Silica PCB EDD and Graphical Report Metals, PCDF
AIRTEK AIRTEK EDD to To AIRTEK Presentation Sent to Hg Reports Report
PM, PM, AIRTEK PM, of PM 10 and AIR'IHK Sent to Sent to
AIRTEK AIRTEK PM, AIRTEK PM2.5 QAO for AIRTEK AIRTEK
QAO& QAO& AIRTEK QAO& Data Sent To: Validation/ QAO for QAO for
AIRTEK AIRTEK QAO & AIRTEK DM US EPA Usability Validation/ Validation/
DM DM AIRTEK Region II - P. Assessment Usability Usability
DM Evangelista Assessment Assessment
NYC DEP - K.
Radhakrishnan
Ongoing Activities
Calculation of 24 hour Averages For PMIO and QA Report (If Issues Noted) and/or For Data Validation
PM2.5 Data Memo Generated for Each Batch of Samples
25