Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - Rev 1 - February 1, 2006
(TEQ) for each sample. The TEQ will be calculated using toxicity equivalency
factors (TEFs) from Interim Procedures for Estimating Risks Associated With
Exposure to Mixtures of Chlorinated Dibenzop- Dioxin and Dibenzofurans (CDDs/
CDFs), EPA-625/3-89-016, March 1989. Each dioxin or furan congener is multiplied
by the associated TEF. The resulting values from each congener are summed to
generate the TEQ. In order to remain conservative, the detection limit for
nondetect results will be used and estimated maximum possible concentrations
(EMPCs) will be included in the calculations. The TEFs which will be used are as
follows:
Dioxins/Furans Congener TEF
2,3,7,8-TCDD__________________ 1.0
2,3,7,8-TCDF__________________ 0.1
1,2,3,7,8-PeCDD_______________ 0.50
1,2,3,7,8-PeCDF________________ .05
2,3,4,7,8-PeCDF________________ 0.5
1,2,3,4,7,8-HxCDD_____________ .10
l.2.3.6.7.S-llxCI)l) .10
Dioxin/Furan Congener TEF
1,2,3,4,7,8-HxCDF_____________ .10
1,2,3,4,7,8-HxCDF_____________ .10
2,3,4,6,7,8-HxCDF_____________ .10
1,2,3,7,8,9-HxCDF_____________ .10
1,2,3,7,8,9-HxCDD_____________ .10
1,2,3,4,6,7,8-HxCDF___________ .01
1,2,3,4,7,8,9-HxCDF___________ .01
1,2,3,4,6,7,8-HxCDD___________ .01
OCDD_______________________ .001
OCDF .001