approach based on the significant uncertainty associated with the numerous factors (such
as activity patterns, sample location, surface characteristics, air exchange rates and room
volume) that influence this relationship. EPA’s use of surface wipe and microvacuum
sampling at its WTC Residential Confirmation Cleaning Study site (110 Eiberty St) was
intended to provide a measure of cleaning effectiveness, and not a risk-based health
assessment.
Risk from asbestos is directly related to its concentration in air. Consequently, post
cleaning aggressive (i.e., use of a leaf blower and fans) air sampling was conducted at
114 Eiberty St. by DEP’s contractors to insure that asbestos levels in air met risk-based
clearance criteria.
The EMSE analytical report does not provide detailed information on sample collection,
however, it appears many samples were collected from inaccessible areas below the
hardwood flooring, or from areas of unknown accessibility such as wall tracking, pipe
shafts and I-beams. The scope of work developed for the clean up activities was
designed for the removal of debris from the collapse of the World Trade Center and did
not include the removal or remediation of pre-existing building materials. As a matter of
precaution, any residual dust and, thus, potential reservoirs of asbestos, from accessible
areas should be cleaned using the technique of vacuuming and wet-wiping.
Asbestos containing materials (ACMs), such as floor tiles, were observed during DEP’s
cleaning of the building. Some of the ACMs may be present under the hardwood
flooring, thus samples collected from this location may be more representative of the
building materials contained within the building rather than indicating contamination
from other sources. Additionally, DEP noted and reported the presence of thermal
system insulation and damaged asbestos-containing fireproofing within the building.
Building representatives were provided with this information and were informed of the
provisions of Title 15, Chapter 1 of the Rules of the City of New York that require the
determination of the presence and quantity of ACM prior to alteration, renovation,
modification, or demolition activities.
It should also be noted that several errors were detected in the calculation of sample
concentrations. Two samples had incorrect concentrations reported, samples 221160-02
and 221160-03 (reported on page 6 of the report) should have reported concentrations of
1,471,401 and 432,765 s/cm’. respectively.
Mold and Bacteria Data
Based upon the results that were received, it appears that one sample was collected for
mold and bacteria from a kitchen floor and counter on the third floor. The sample was
analyzed by P&K Microbiology Services, Inc. with the number and type of fungi and
bacteria being counted and identified. Seven fungi species were identified with the
highest count for any one species being 900 colony forming units/square inch (CFU/iir )
and a total sum of 2,200 CEU/in^, while six bacteria species were identified with the