Title: QAPP - Extent of WTC Impacts to the Indoor Environment Date: April 2005

This section details the Quality Assurance/Quality Control (QA/QC) requirements for field activities performed during the sampling effort.

Field spike samples shall be collected for lead analysis in order to assess if the laboratory digestion procedure used for the wipe material is capable of achieving recovery within the QC limits of 80 to 120 %. A summary of the results for the spiked samples and the calculated percent recovery shall be provided in the final report. The results of the spike samples should be able to determine if the laboratory is able to achieve the recovery required for the analysis of lead wipe samples within the QC limits.

Field spike wipe samples for lead analysis shall be prepared by the laboratory. The spike samples shall be sent to the sampling contractor and shall be randomly inserted into the sample group for each building, for each day of sampling.

It should be noted that microvacuum and wipe sample field duplicates shall be co-located as close as possible to the original sample template.

QA/QC samples shall include the collection of one field duplicate and one matrix spike/matrix spike duplicate sample for each sampling technique at a ratio of 1 per 10 samples for each parameter. Extra sample volume shall be submitted to allow the laboratory to perform matrix spike sample analysis. This analysis provides information about the effect of sample matrix on digestion and measurement methodology. Field duplicate samples provide an indication of analytical variability and analytical error and shall not be identified to the laboratory.

Field blank samples shall be collected to determine if the sample media could become contaminated during the sampling event. One field blank (the field blank is opened inside of the unit, exposed) shall be collected for each parameter for every unit and HVAC that is sampled (HEPA vacuum, microvacuum, bulk, wipe). These samples are to be collected by removing the media from its container or package, handling as it as would be done during the actual sampling procedure and placing the media back into the sample container. Results of these samples shall determine if any contamination was detected above the reporting limit or established benchmarks for this program that would affect the results or quality of the data.

Lot blanks samples shall be collected to determine if the media used to collect the samples was contaminated. One lot blank (unopened media) shall be collected for each parameter each day (from HEPA vacuum, microvacuum, bulk, and wipe). Results of these samples shall determine if any contamination was detected in the sampling media above the reporting limit or established benchmarks for this program that would affect the results or quality of the data.

11.0 DATA MANAGEMENT TASKS

-30-

CITY_21MC100_002649203

NYC-WTC_000442693

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000442693Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000176016

Draft contract document outlining the scope for collecting and analyzing settled and airborne dust samples in fourteen buildings.

Similar indexed content

Compare copies and versions →