Part V - Quality Assurance Project Plan
133-135 Greenwich Slreet/21-23 Thames Street
Airtek Project 05-0701 - November 4, 2005
QA/QC samples will be collected to assist in the interpretation and validation of the
laboratory analytical results. The QA/QC samples that will be collected during this
characterization sampling program include field duplicates or co-located samples (10
percent of samples). Field duplicate samples will be collected as a check on laboratory
accuracy and precision. One duplicate dust sample will be collected from the bulk dust
and or high-efficiency particulate air (HEPA) filters. The duplicate sample will be placed
in the appropriate, clean, laboratory-prepared sample containers and analyzed for the
same parameters.
Precision for laboratory and field measurements will be expressed as the relative percent
difference between two duplicate determinations. Acceptance criteria for laboratory
precision will be those specified in the method or +/- 20 percent if not otherwise stated
Data validation will be carried out upon receipt of all laboratory documents. Sample results will
be evaluated to assess potential usability issues. The reported results of all QC checks and
analytical procedures will evaluated, including holding times, sample preservation techniques,
QC sample results, etc. QC
samples reviewed to identify potential problems in any of three specific areas:
laboratory/insfrument performance, sample preparation/matrix effects, and field performance.
Laboratory and instmment performance will evaluated by reviewing laboratory blank
contamination and instrument calibration data provided by the laboratory. Any unusual matrix
effects will be detected by examining the results from mafrix spike/matrix spike duplicates,
surrogate spike recoveries, and internal standard responses as reported by the laboratory.
Potential problems originating from field sampling work will be
evaluated by examining the field duplicate, equipment blank, and trip blank results.
If the evaluation of QC checks indicate laboratory or field problems, then their impact on the data
will be reported with the sample results.
Before reporting results, raw data will be reviewed in detail to verify the accuracy of the results
reported by the laboratory.
More detailed information is available from individual SOPs for the test of interest or the
published method.
Table 10-1
RCRA Waste Characterization Analytical Method, Container, Preservation and Holding
Times for selected aqueous and non-aqueous matrices.
Min Container Sample Holding
AnaMe Method volume Type Preservation Time
(niL)
Acidity EPA 305.1/SM 2310 B 1000 P,G Cool, 4 “C 14 days
Alkalinity EPA 310.1/SM 2320 B 1000 P, G Cool, 4 "C 14 days
Chlorinated EPA 608/ SW 8080 1000 GA Cool, 4 “C 7/14
Pesticides and days
PCB’s