Title: QAPP - Extent of WTC Impacts to the Indoor Environment Date: April 2005

Wipe samples will be analyzed for the contaminants of potential concern (COPC) lead and polycyclic aromatic hydrocarbons (PAHs), microvac samples will be analyzed for the COPC asbestos and man-made vitreous fibers (MMVFs); and bulk dust and HEPA vacuum samples will be analyzed for the COPC and to screen for the presence of WTC dust (see Table 12 below). Wipe and microvac samples will be taken in proximate locations, so that for each location sampled within a unit, there will be measurements of the four COPC. Further detail on the strategy for unit selection, and then to select locations within units to sample are provided in Attachment 4 (Indoor Dust Sampling Protocols) of the QAAP.

Table 12. Sampling Technique and Parameters to be Analyzed

Sampling Technique Lead PAHs Asbestos MMVF WTC Signature

wipes X X

microvac X X

bulk/HEPA X X X X X

The analytical results from these samples will be used to determine whether or not a cleaning will be offered to the occupant or owner of the unit being tested. Results from all units of a building will be used to determine whether a full building cleanup will be offered, and results from the study as a whole will be used to determine what further activities with regard to sampling or cleanup are warranted. Details on the criteria used to make these decisions are described in Section G of the SAP. Further, it should be noted that source attribution will be a critical factor in determining whether to re-clean if an initial cleaning is deemed necessary. A source survey will be conducted where exceedances are found and if it is found that the exceedance is due to a source within the building or adjacent to the building, no further cleaning or resampling to demonstrate clearance will be offered. Although most pertinent to lead, the same principle applies to the other COPC - if the exceedances resulting in the building cleanup can be attributed to a source within or adjacent to the building, no further cleaning or resampling to demonstrate clearance will be offered. Details on the survey(s) to be conducted can be found in Attachment 4 of the QAPP.

In order to characterize central HVAC units in buildings which have full or partial central HVAC units (“full” is defined as units serving both common areas and individual apartments, offices, etc; while “partial” is defined as units serving only common areas while apartments or offices have individual units), samples shall be taken by the Primary Contractor and/or its Sub-Contractor as specified in Attachment 7 of the QAPP and paraphrased below: 1) at least one HEPA vacuum composite sample per building from outdoor air inlets to HVAC; 2) at least one HEPA vacuum

-19-

CITY_21MC100_002649192

NYC-WTC_000442682

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000442682Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000176016

Draft contract document outlining the scope for collecting and analyzing settled and airborne dust samples in fourteen buildings.

Similar indexed content

Compare copies and versions →