with the approved Quality Assurance Project Plan (QAPP) for the WTC Background Study, dated August 2002. The procedures used for sample collection, analysis, data validation and management are described or provided as an attachment to the approved QAPP which will be furnished upon request.

4.1 Sampling Procedures Samples were collected from twenty five residential units and 9 common spaces (i.e., seven basement laundry rooms and two hallways). Sampling consisted of: indoor air samples of airborne fibers and particulate matter; microvacuum samples of settled dust on carpeting, area rugs, upholstered fabric furniture and/or drapery; y^pe samples of settled dust from ceilings, walls, bare floors, counter tops or table tc^s; and bulk dust samples fi-om window air conditioner filters. All samples were collected from areas routinely used and occupied by residents, such as, living rooms or bedrooms and in common areas, such as, entrance hallways or basement laimdry rooms.

A summary of the sltople collection and analytical procedures used are provided in Table 4-1 of this report. The following subsections provide brief descriptions of the sampling proc&ures to place the subsequent discussion of results in context.

4.1.1 Indoor Air Sample Collection Airborne fibers and particulate matter were collected by drawing a known volume of air through a filter membrane cassette following the procedures specified in Table 4-1. When available and permifted by the resident or building manager, some of the air sampling was conducted employing the use of oscillating fans and/or operating the window air conditioning units. The use of fans or window air conditioners was to simulate typical household activity within each unit. The equipment used for the collection of air samples is propSdn Section 4.2 of this report.

The collection of air samples did not employ the use of aggressive techniques (i.e., using electric leaf blowers to agitate dust) due to the risk of dust exposure to the residents or persons in each unit during the sampling activities.

4.1.2 Microvacuum Sample Collection ' Samples of settled dust were collected from porous surfaces using microvacuum techniques and analyzed for asbestos and lead. Porous surfaces included carpet, area rugs, upholstered couches, chairs, ottomans and in some cases drapery when furniture and/or carpet were not available. The intended use of the microvacuum method was to determine the presence or absence of asbestos and lead contaminants.

The standard test method used for the collection of asbestos micorvac samples is referenced in Table 4-1. This method describes the procedures for collecting non- airbome dust samples. It is stated in sub-section 1.2.1 of the ASTM Standard D WORLD TRADE CENTER BACKGROUND STUDY 9

CITY_21MC100_011105500

NYC-WTC_000301626

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000301626Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000320385

Oldraft report for World Trade Center background study prepared for FEMA, EPA Region 2.

Similar indexed content

NYC-WTC_000418482

WTC background study interim final report prepared for FEMA and EPA contractors.

Similar indexed content

Compare copies and versions →