in Table 4-1 of this report. The following subsections provide brief descriptions of the sampling procedures to place the subsequent discussion of results in context.

4.1.1 Indoor Air Sample Collection Airborne fibers and particulate matter were collected by drawing a known volume of air through a filter membrane cassette following the procedures specified in Table 4-1. The equipment used for the collection of air samples is provided in Section 4.2 of this report.

When available and permitted by the resident or building manager, some of the air sampling was conducted employing the use of oscillating fans and/or operating the window air conditioning units. How the air conditioning units were utilized during sampling depended upon the unit’s features. For example, some units had the option to recirculate interior air or use outside air. When this option was available, the unit was set to recirculate interior room air. Other units did not have this option. The intended purpose for the use of fans or window air conditioners was to simulate typical household activity within each unit.

The collection of air samples did not employ the use of aggressive techniques due to the risk of dust exposure to the residents or persons in each unit during the sampling activities. Aggressive sampling techniques employ the use of electric leaf blowers with a maximum velocity ranging from 140 miles per hour (mph) to 225 mph, and maximum air volumes ranging from 78 cubic feet per minute (cfm) to 425 cfm in order to agitate dust into the air. The dust then remains suspended in air by using fans. The aggressive techniques do not simulate “normal” household activity or living conditions. However, as the goal of the Study was to estimate background concentrations under typical conditions, the use of non- aggressive sampling techniques is more representative of typical household activity and living conditions.

4.1.2 Microvacuum Sample Collection Samples of settled dust were collected from porous surfaces using microvacuum techniques and analyzed for asbestos and lead. Porous surfaces included carpet, area rugs, upholstered couches, chairs, ottomans and in some cases drapery when furniture and/or carpet were not available.

The standard test method used for the collection of asbestos microvacuum samples is referenced in Table 4-1. This method describes the procedures for collecting non-airbome dust samples. It is stated in sub-section 1.2.1 of the ASTM Standard D 5755-95 that “The collection efficiency of this technique is unknown and will vary among substrates. Properties influencing collection efficiency include surface texture, adhesiveness, electrostatic properties and other factors.” Due to the limitation of the microvacuum sample collection method for asbestos, the intended use of the method was to determine only the presence or absence of asbestos contaminants.

WORLD TRADE CENTER BACKGROUND STUDY 12

CITY_21MC100_0 12423920

NYC-WTC_000418499

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000418499Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000320385

Oldraft report for World Trade Center background study prepared for FEMA, EPA Region 2.

Similar indexed content

Compare copies and versions →