Title: QAPP - Extent of WTC Impacts to the Indoor Environment Date: April 2005

collapse plume, and to sample enough units within the building so as to be able to adequately characterize the building as a whole. Units facing the World Trade Center site are those which are the most likely to have become contaminated based on their orientation with respect to the collapse plume as might be units with air supplied through a similarly impacted HVAC which serves their units. There may be reason to deviate from this procedure to, for example, sample only one unit in a single story building.

7.2 Sampling Procedures and Requirements

The Contractor shall collect samples for asbestos, MMVF, lead, PAHs, and WTC dust screening components as well as QC samples, in accordance with this QAPP and Attachment 4, Indoor Dust Sampling Protocols.

Quality control (QC) samples shall be used to assess the sampling and analytical processes and to ensure that these processes are being conducted properly. QC samples shall be collected during each day of sampling. These samples include the collection of field spike samples, field blanks, duplicates, and lot blanks (see Section 10.1, Sampling and Analytical Quality Control Samples for details).

The Primary Contractor and/or its Sub-Contractor shall collect wipe, micro-vacuum, HVAC filter, and HEPA vacuum samples from a minimum of 150 residential and non-residential buildings, as well as from central heating, ventilation, and air conditioning (HVAC) units, as determined by the EPA. The Primary Contractor and/or its Sub-Contractor shall perform all field activities utilizing the appropriate field sampling and analytical methods as specified in Tables 4 and 6.

Three sets of dust samples shall be taken within each unit as specified in Attachment 7 of the QAPP: 1) three or more samples at locations where dust-related exposures are likely to occur, such as in elevated horizontal surfaces (e.g., desk or table tops) and floors, 2) three or more samples at locations where WTC dust may have accumulated but has not frequently been cleaned, such as on top of cabinets and 3) a single composite sample from “inaccessible” locations where cleaning is unlikely, such as behind a refrigerator. The first set of samples will be termed, “accessible” samples and the second, “infrequently accessed” samples, the third “inaccessible” samples. Samples from the first two locations will be taken by wipes and microvacs. These samples will yield results in load (weight or fibers per unit area) and will be compared to benchmarks. The sample from the third set of locations (“inaccessible”) will be bulk dust samples or collected by HEPA vacuums and will yield results in concentration (weight or fibers of contaminant per weight of sample). The “inaccessible” area sample results will be used for signature screening and considered with modeling and monitoring results in determining the geographic extent of the distribution of dust from the WTC collapse. “Inaccessible” area sample results will not trigger a cleaning.

-18-

CITY_21MC100_002649191

NYC-WTC_000442681

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000442681Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000176016

Draft contract document outlining the scope for collecting and analyzing settled and airborne dust samples in fourteen buildings.

Similar indexed content

Compare copies and versions →