NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 117 pages

Ambient Air Monitoring Program, Draft PBP

Machine-extracted title · confidence 51%

Quality Assurance Project Plan for ambient air monitoring at 130 Liberty Street deconstruction, Aug 2005.

NYC-WTC_000441561–000441677
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Ambient Air Monitoring Program Section No. 13 Quality Assurance Project Plan Revision No.: 0 130 1 .iberty Street - NY, NY Date: August 2005 Lower Manhattan Development Corporation Page 84 of 116

I’M I (I and PM 2 5 I sing a Reference Sam pier

Tables 13-ld summarizes major maintenance activities for the PMio and PM2.5 samplers. The manufacturer’s documentation should be consulted for a more exhaustive list of maintenance and inspection procedures.

Table 13-ld. Maintenance, Testing, and Inspection Requirement for the Anderson RAAS Sampler Used for FM m and PMi - Acceptance Equipment Frequency/Method Corrective Action Criteria Sampler Dismantle and clean at No obvious Clean or replace inlet/receiver tube manufacturer specified particulate deposits or damaged equipment intervals damage before sampling Power cords Check for crimps or No obvious damage Replace as necessary cracks O-Rings At 3 month intervals, No leaks or Replace as necessary inspect all 0-rings in the compression damage sampler evident Tubing and fittings Visually inspect on No crimps, cracks, or Replace as necessary sample recovery days obstructions; no crossthreading Vacuum pump Replace diaphragm of NA NA vacuum pump annually

• Field QC Flow Check - The field technicians should perform a single point flow check at the normal operating flow rate on a monthly basis. If the results of the field flow check exceed +10% of the flow rate indicated by the sampler, the sampler should be serviced (if necessary) and a new, full multipoint calibration should be performed.

Leak Check - The filter used in the sampler is contained within a cassette. A daily leak check is necessary to demonstrate that the portion of the sample flow rate that leaks past the filter without passing through the filter is insignificant relative to the design flow rate of the sampler. The leak check should be peiTormed at 55 mm Hg vacuum or better. Record the initial vacuum. After ten (10) minutes record the final vacuum. Consult the manufacturer’s documentation to find the acceptable criteria for the difference between the initial and final vacuums. This criteria is sampler dependent as it must take into account the internal volume of the sampler under vacuum.

PM I (I and PM 2 5 Using a Met One E-BAM Continuous Monitor

Maintenance, testing, and inspection requirements for the E-BAM continuous monitors are as follows.

• Audit flow system periodically by performing leak checks and flow audits.

L2005-346 Rev. 1

CITY_21MC100_003243490

NYC-WTC_000441645

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000441645Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000449648

Draft QA Plan for ambient air monitoring at 130 Liberty Street deconstruction project, Aug 2005.

Similar indexed content

NYC-WTC_000444248

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

NYC-WTC_000447031

QA plan document for ambient air monitoring program for Liberty Street deconstruction.

Similar indexed content

NYC-WTC_000449908

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 7, 2005.

Similar indexed content

Compare copies and versions →