Ambient Air Monitoring Program Section No. 10 Quality Assurance Project Plan Revision No.: 0 130 Liberty Street - NY, NY Date: September 1, 2005 Lower Manhattan Development Corporation Page 70 of 124

PMio sampler will be collocated along side the real-time PMw monitors as a QA check. The Anderson RAAS sampler will rotate on a monthly basis through all real-time PMio monitor locations for the duration of the monitoring program.

10.2.9.1 PMio - Reference Method via Anderson RAAS samplers

Particulate samples whose aerodynamic diameter is < 10 q will be collected using Andersen RAAS samplers operating in the PMw mode. All samples will be collected over an estimated twenty-four hour sampling interval at a prescribed flow rate of 16.67 liters/minute. This equates to a corrected air volume of 24 m^ per each twenty-four hour sampling event. Pre-weighed Teflon filters (47mm diameter) provided by the subcontracted laboratory will be placed in the RAAS sampler cassette prior to the start of each sampling event.

The sampler specification for the PMw sampler is contained in 40 CFR Part 50 Appendix J. This document specifies the PMw sampling limits, protocol, and instrument specifications. The RAAS systems perform all of the functions required or recommended in the instrument specification part of the standard. The inlet has a 10-micrometer (nominal) cutpoint. The inlet provides wind speed and direction independent sampling and removes particles larger than about 10 micrometers.

Before sampling, the filters are equilibrated to constant temperature and relative humidity conditions and weighed. After sampling, the filters are again equilibrated to the constant temperature and humidity conditions and weighed. The mass concentration is then calculated by dividing the weight of the particulate captured on the filter by the volume of air (at ambient conditions) that passed through the sampler. The flow rate is required to be maintained within 5% of 16.67 liters per minute with a coefficient of variation (a measure of the average short-term variation in flow in %) of less than 2%.

Equipment and supplies utilized with this sampling approach are as follows:

• Filters - Preweighed 47-mm Teflon® filters. Filters should be stored and transported in petri dishes.

• Forceps - Non-serrated forceps should be used to handle the 47-mm filters.

• Anderson RAAS PMw Sampler - A sampling system that meets the requirements of 40 CFR Part 50 Appendix J for the sampling of PMw when operated in the PMw mode. The Anderson RAAS sampler design incorporates a flow-indicating device, a thermometer, a barometer, and a timing control device into the sample monitor.

Manometer - A water or oil manometer is used to calibrate the flows of the PMw samplers.

• Timing/Control Device - A timing device capable of starting and stopping the sampler to obtain an elapsed run time of 24 hr ±1 hr. The accuracy of the timing device should be ±15

L2005-346 Rev. 1

CITY_21MC100_011977800

NYC-WTC_000440610

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000440610Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000444248

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

NYC-WTC_000441561

Quality Assurance Project Plan for ambient air monitoring at 130 Liberty Street deconstruction, Aug 2005.

Similar indexed content

NYC-WTC_000443239

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, LMDC.

Similar indexed content

Compare copies and versions →