NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 68 pages

WTC environmental plan, EPA review, 2005

Machine-extracted title · confidence 46%

EPA-compiled plan for Environmental Community Air Monitoring Program, 2005.

NYC-WTC_000437748–000437815
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Department of Transportation (DOT) hazardous materials shipping First Aid and Cardiopulmonary Resuscitation (CPR) training

A9. DOCUMENTS AND RECORDS

The RE AC Program QAPP serves as the basis for this generic QAPP. The most current approved version is available to all REAC technical personnel as an uncontrolled copy on the REAC Local Area Network (LAN). Documents and records that will be generated during this project include:

WP Draft Generic QAPP Final Generic QAPP Field logbooks Site maps Photos of Sampling Locations Chain of Custody forms Final Reports

The Final Report will provide a description of the project, field procedures, sample preparation procedures, difficulties encountered and will include validated final copies of chain of custody forms. All documentation will be recorded in accordance with REAC standard operating procedure (SOP) #2002, Sample Documentation and REAC SOP #4001, Logbook Documentation. The final report will be prepared using REAC SOP #4021, Preparation of Final Reports.

B, DATA GENERATION AND ACQUISITION

B1. SAMPLING PLAN DESIGN

Judgmental sampling will be used to select sample locations that are most likely to represent WTC residue or background dust. This will be based on historical information, visual inspection and best professional judgment of the WAM and sampling team. This type of sampling is used to identify contaminants present in areas potentially having the highest concentration of contaminants. Additional samples may be collected when requested by the WAM and EPA NHSRC personnel.

During the sampling of EPA specified buildings, dust samples will be collected from each of the buildings up to 20 in accordance with the EPA approved generic QAPP. Sampling will likely be performed at two types of areas in each building: a high traffic area (to characterize tracked-in dust) and a lowtraffic area (to represent settled indoor dust). Two low traffic areas will be specified for a total of three areas that will be sampled. The desired high traffic area is to be an area near a main entrance, preferably carpeted. The desired low-traffic areas include areas infrequently cleaned, such as the top of elevator housing, under refrigerators, behind file cabinets, above ceiling tiles, on high shelves, or in other areas that show visible dust accumulation and are infrequently disturbed. Sampling will not be restricted to carpeted areas as the intent of the sampling is to obtain the desired residue. If vacuum sampling is not possible or preferred, sweep sampling will be used to collect the residue. Sampling will not be conducted in areas that would likely contain chemicals in dusts that would interfere with the analysis for the WTC markers. The following areas will be avoided in the sampling effort:

Areas with significant cigarette or cigar smoke, incense, or burning candles Areas near major outdoor combustion sources (e.g., power plants)

Due to the inability to obtain triplicate samples (once an area is sampled, little residual remains), three samples will be collected in the same general area, for a total of nine samples from a building (i.e., three sample areas times three samples in each general area). The proximity of the samples in

26

CITY_21MC100_0 03219515

NYC-WTC_000437773

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000437773Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →