Iwrtc residential plan oct29.wpd Page2j
****DRAFT Version 10, October 29, 2001**^-^
Infonnation from residents support the need to further assess potential indoor and outdoor
environmental health issues. Burning throats have been reported to be a common problem in the
recently re-occupied residential areas. Residents in south Battery Park City, whose windows
were open at the time of the WTC collapse, have settled dust in their homes. Some have
disposed of furniture, stereo equipment, etc., because they were covered with "ash and dust."
Homes in part of the Tribeca zone (Chambers Street to Murray Street, west of Broadway) are not
yet occupied, but were reported to have roofs covered witli hand-sized chunk s of insulation-like
material that contain small pieces of mica-like material. In addition, the mica-like material has
clogged roof drains and resulted m standing pools of water on residential roof tops.
n. Sampling Objective:
The overall objective of this sampling is to provide results upon which public health agencies can
further determine the potential for environmental exposures to WTC collapse-related materials
and possible health impheations of the exposures. Sampling will characterize ambient and indoor
airborne and potentially airborne particles (surface dust) in residential areas of lower Manhattan
from the collapse of the World Trade Center. Specifically, the objective is:
Characterize the make-up and size distribution of settled dust and airborne breathing
zone dust in residential areas-both indoors and outside-near the WTC. This information
will be used to further determine if materials are present in air at levels; of public health
concern; and if materials are present in settled surface dust that can be re-entrained and
result in continued exposures.
Sample locations will be selected in a concentric circle pattern, starting close to the WTC and
ending in neighboring boroughs. Section V, Residence Selection/Sampling rationale, of this
protocol describes this approach.
Note: The sampling objective/approach is focused on contaminants that emanated from the
collapse of the WTC towers and that might cause health problems. However, this investigation
will not be able to conclude if contaminants/materials are actually from the disaster. The
contaminants that have been selected for testing might be present in some areas from other
sources. Examples include: cooking on a stove top can increase indoor airborne particulate
matter; vehicle exhaust can increase outdoor airborne particulate matter; recent home renovation
can result in an increase in levels of gypsum, fiberglass, etc. in the air and surface dust.
HI- Data and Quality Assurance:
Co-located samples will be collected in 10% of the air samples. While not a true duplicate,
evaluation of the results will provide some information on the quality of the sampling technique.
Generally, analysis of duplicate samples should be within ■+■/- 20% of each other.