not know which samples were pure background dust, and which were background dust samples spiked with WTC dust. The labs have several weeks to analyze all dust samples. They have been asked to provide data as to the quantity of screening materials present in the dust in a standardized format (Appendix B). The final data from all laboratories will be evaluated to determine if they were able to distinguish background samples from WTC spiked samples. In addition, criteria such as time for analysis, and intra- and interlaboratory variability will be considered when determining validity of the method.

A.6.4 Tasks and Timeframes

Sample Collection September 2004-May 2005 Method/Protocol Development February 2005-June 2005 Screening Study June 2005-August 2005 Completion of Reports August 2005 Peer Review August 2005-September 2005

A7. Quality Objectives and Criteria

A7.1 Data Quality Objectives (DQOs)

The data quality objectives for this project are based on data acquired in the methods development stage of this study. An inter-lab data quality objective was determined using the variability within each dust sample for slag wool fibers, one of the markers for WTC dust. It was determined that data could be acquired with a relative certainty of + 35%. An intra-lab data quality objective was determined using the variability within each dust sample for slag wool as well. It was determined that data could be acquired with a relative certainty of + 30%.

A7.2 Measurement Quality Objectives (MQOs)

The accompanying tables (Tables 1 and 2) list Measurement Quality Objectives (MQOs) for this intralaboratory (within lab) and interlaboratory (within sample) variability. Accuracies and precision were taken from preliminary data and manufacturer’s specifications.

Measurement Analysis MQO for MQO for MQO for Parameter Method Accuracy Precision Completeness Individual dust Microbalance +/- 5% +/- 5% 85% sample mass Fibers/Concrete Particles/Gypsum SEM +/- 30% +/- 30% 85% Particles Fibers PLM +/- 30% +/- 30% 85%

Table 1: Measurement Quality Objectives (MQOs) for Intralaboratory Variability (within lab)

13

CITY_21MC100_0 03219502

NYC-WTC_000437760

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000437760Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →