a ATC Environmental, Inc. 104 East 25th-Street I ATC Associates Inc. New York, New York 10010

Approved N.Y. State ELAP #10879

I 104 East 25th Street New York, NY 10010 ACCREDITED NVLAP Lab Code # 1187 Report Date: 09/29/01 ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) I With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

lll^ Sample Identification Analysis Parameters

Project/Site; 40 Rector Street, NY, MY TEM Sample No.: 557S - 55738

I Foors 6, 7 3, 4, 11, 2. 1/Lobbv Date Received:09/29^^ Grid Openings Analyzed:._ 6

Project Sample No.; T15 Average Grid Opening; 106.00 urn

I Air Volume: 1270 liters Total Area Analyzed: 0.0674 mni2

I Filter Type; MCE 25 mm diam., Pore Size; Q.45 um Effective Area; 385 mrn2 Analytical Sensitivity: 14.8 s/Tnni2 0.0045 s/cc

H FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total

I Single Fibers Bundles Clusters Matrix struct, Total. struct Struct. >=5ura Struct/mmS Filter Struct/cc Air ngm/mS

I „..... 0 a 0 0 0 0 0.0 0.0000 0

, Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos D 0 0 0 0 0 0.0 0.0000 N/A UH No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

I fc - Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis- is 1 standard deviation.

Won-asbestos fiber i.d. (EDS/SAED): None detected I Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This -laboratory is in compliance with the quality specified for the method.

Analyzed by; Report Reviewed by.

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

—

CITY_21MC100_007087989

NYC-WTC_000437435

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000437435Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000117493 · Box DEP Box 46

Cover page for a report detailing annual assessment, bulk sampling, and air monitoring activities at the specified address.

Similar indexed content

Compare copies and versions →