ATC Rector Street asbestos air sampling summary

Machine-extracted title · confidence 34%

Summary report presenting five ambient air samples per floor for Rector Street office building.

NYC-WTC_000437380
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document ’ -qL-i --------------------- —---------------- uvl AM gmax XJ.BI i , iu.ui

'Kustawsis I CWTC .... ..... *a i b c IAT c s I M e. F^212^;S3»

VIA FACSIMILE 212-371-1084

October 24.2001

40 RECTOR HOLDINGS. LLC e/0 TANNENBAUM HELPERN SYRACUSE & HIRSCHTRITT LLP 900 Third Avenue NowYortr. NewYofU 10022-1/76 A«n; Mr. Soott Furman

40 RfiCTOR STREET. New York

Dear Mr. Fumum: ATC Assoclatei Inc. (ATC) is pleased to submit this aummoty report presenting the asbestoe air sample results for toe first through nineteenth floora of 40 Rector Street Between October 22 and 23.2001, ATC collected five ambient air samples per floor, totaling 90 samples to ascertain the presence or absence of airborne asbestos, within toe subject facility. Alt samples collected were anatyzad in accordance with the AHERA Transmission Electron Microscopy (TEM) method as set forth at 40 CFR Part 763. Subpart E, Appendix A. Acceptable ambient air eemples resutta are those sample sets meeting toe AHERA re-occupancy requirement following an asbestos abatement action of an average of less than 70 asbestos structures per square millimeter (<7Q simm’). Summary of Ambient Ar Sample Results for 40 Rector Street; Floor Analytical Result I Floor Analytical Result 1 No structures detected 10 No structures dateetod 2 No structurM detected 11 No structures datoctad 3 NO structures detected 12 No atructuraa detected 4 No structures deteotod i2~ b/o atruduros datacted S No structures detaotsd 1S No structurea detected 6 No structures detect^ iT" Nostructoras doiectod 7 No structures detected 17 No structuros dataded 8 No structures deffioted -^1?“ No stnictures detected 9 No structuras deiaetad T5~ Nd structuras detsetad Based upon the analytical results within The AHERA claaranoe requirement, it is ATC's opinion that the ambient air sample collected throughout the building meet an acceptable criterion for ra-occupancy. If you have any quezOont or require additional explalnatlon of tha information presented plusa do not heeitate to call me at 212-353-8290 Sincemly,

Fred BurWiardt Senior Project Managar ATC AwocUtes Inc.

*» TDTRU PfiGE.Oa »*

/

NYC-WTC_000437380

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000437380Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000291213

AS asbestos air sample results for first-to-nineteenth floors; summary report.

Similar indexed content

Compare copies and versions →