NYC 9/11 Public Portal Document
NVC Response
Asbestos Air Sampling Results for WTC Extended Network
Sampling Date and Time: 01/20/02 1200 to 2400 Data Validation Date: 01/24/2002
PCM by MIOSH 7400 TEM f AHERA)
Sampling Sampling Sample Structures (#)
Date Sample No, Location Volume (L)" Matrix f/mm^ f/ec 0,5p - Sp 5p S/mm^ S~f/cc*
01/20/02 7093-18-0115 Park Row 1352 Air 11.46 0.003 0 0 <16.00 <0.0046
01/20/02 7093-19-0115 Chambers Street 1266 Air <7.0 <0.002 0 0 <16.00 <0.0049
01/20/02 7093-15- Manhattan PS #143 NS Air NS NS NS NS NS NS
01/20/02 7094-09-01 03 Bronx PS #154 1342 Air <7.0 <0.002 0 0 <16.00 <0.0046
01/20/02 7096-12-0109 Queens PS #199 11 92*** Air <7.0 <0.002 0 0 <13.33 <0.0043
01/20/02 7095-98-01 09 Brooklyn PS #274 1376 Air <7.0 <0.002 0 0 <16.00 <0.0045
01/20/02 7097-18-0106 Staten Island PS #44 1098*** Air <7.0 <0.002 0 0 <13.33 <0.0047
Key:
‘Structure (S) roughly equivalent to fiber (f)
** Sample volume is based on pump reading
*** Sample volume is below recommended limit for TEM analysis
**** Chrysotile
NR - analysis not requested
NS - Sample not submitted due to no access to station location
n/a- Not applicable
NiOSH 7400: Fiber Analysis of Air samples via NIOSH 7400, Revision 3, issue 2, 8/15/94
o
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) EPA 40CFR Part 763 (AHERA)
H
Standard criteria: EPA 40CFR Part 763 (AHERA): 0.01 fiber/cc (PCM), 70 S/nm^ volume 1200 L, for 25 mm filter (TEM)
to
s
o
o
o
Io DOH00175499.XLS
to
o
to
NYC-WTC_000436862
OCR can misread numbers and units. Confirm readings against the page image before using them.