NVC Response
Asbestos Air Sampling Results for WTC Extended Network
Sampling Date and Time: 01/04/02 1200 to 2400
Data Validation Date: 01/07/2002
PCM by NiOSH 7400 TEM ( AHERA)
Sampling Sampling Sample Structures (#)
Date Sampie No. Location Volume (L)" Matrix f/mm’ f/cc O.Su- 5p 5p S/mm® S~f/cc'
01/04/02 ^093-18-009S Park Row 1440 Air <7.0 <0.002 0 0 <16.00 <0.0043
01/04/02 ^093-19-009£iambers Stre 1404 Air 7.64 0.002 0 0 <16.00 <0.0044
01/04/02 ^093-15-0097 nhattan IS #1 1440 Air <7.0 <0.002 0 0 <16.00 <0.0043
01/04/02 'Og-i-Og-OOSSronxPSfflS. 1284 Air <7.0 <0.002 0 0 <16.00 <0.0048
01/04/02 ^096-12-0093 jeens PS #15 854*** Air <7.0 <0.003 0 0 <10.00 <0.0045
01/04/02 ^095-98-0093 joklyn PS #2 1320 Air <7.0 <0.002 0 0 <16.00 <0.0047
01/04/02 ^097-18-009Cen Island PS 1440 Air <7.0 <0.002 0 0 <16.00 <0.0043
Key:
NS: Not sampled
‘Structure (S) roughly equivalent to fiber (f)
** Sample volume is based on pump reading
*** Sample volume is below recommended limit for TEM analysis
NA<^>: not analyzed due to overloading of particulates
NA<i>: not analyzed for TEM
‘ Chrysotile
Sample volume is below recommended limit for TEM analysis
****‘ Chrysotile
NR - analysis not requested
NS - Sample not submitted for analysis
n/a - Not applicable
NIOSH 7400: Fiber Analysis of Air samples via NIOSH 7400, Revision 3, Issue 2, 8/15/94
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) EPA 40CFR Part 763 (AHERA)
Standard criteria: EPA 40CFR Part 763 (AHERA): 0,01 fiber/cc (PCM), 70 S/mm’, volume 1200 L, for 25 mm filter (TEM)