NYC Response Asbestos Air Sampling ResuSts for Staten island Landfiii Sampling Date and Time 7/17/20020723 to 2202 Date VaSidatioii Date; 07/2Q/20Q2

PCM by NiOSH 7400 ___________ TEM ( AHERA) Sampling Sampling Sample Structures (#) Date Sample No. Location Volume* Matrix f/mm^ f/cc O.Sp - 5p 5!^ S/mm" S~f/cc‘* 07/17/02 LF05769 P-1 1189.80 Air <7.0 <0.002 0 0 <13.12 <0.0042 07/17/02 LF05770 P-2 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 07/17/02 LF05771 P-3 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 07/17/02 LF05772 P-4 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 07/17/02 LF05773 P-5 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 07/17/02 LF05774 P-6 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 07/17/02 LF05775 P-7 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 07/17/02 LF05776 P-8 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 07/17/02 LF05777 W-12A 1296.00 Air 7.64 0.002 0 0 <15.75 <0.0047 07/17/02 LF05778 W-12B 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 07/17/02 LF05779 T-15 1332.00 Air 8.92 0.003 0 0 <15.75 <0.0046 07/17/02 LF05780 T-16 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 07/17/02 LF05781 0-17 1332.00 Air <7.0 <0.002 0 0 <15.75 <0.0046 07/17/02 LF05782 0-18 1332.00 Air <7.0 <0.002 0 0 <15.75 <0.0046 07/17/02 LF05783 0-19 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 07/17/02 LF05784 Lot Blank 0.00 Air <7.0 n/a NA<^> NA<=^> NA<=^> NA<=^> 07/17/02 LF05785 Trip Blank 0.00 Air <7.0 n/a NA(^> NA® NA(=^> NA®

Key; * Some sample volume (liters) are below recommended limit for the TEM method; volume is based on pump reading ** Structure (S) is roughly equivalent to fiber (f) *** Chrysotile **** Actinolite ““‘Amosite NA <’) - Not analyzed due to overloading of particulates NA - Not analyzed for TEM NA - Not analyzed due to wet filter n/a - Not applicable NR - Not requested NS - Sample not submitted R - Sample data rejected due to no sample volume NC - Sample not collected NS - Sample not submitted

NiOSH 7400: Fiber Analysis of Air samples via NIOSH 7400, Revision 3, issue 2, 8/15/94 O Asbestos Fiber Analysis by Transmission Eiectron Microscopy (TEM) ERA 40CFR Part 763 (AHERA) H Standard criteria: EPA 40CFR Part 763 (AHERA); 0,01 fiber/cc (PCM), 70 S/mm’, volume 1200 L, for 25 mm filter (TEM)

to s o o o I Ln o

to o to co wo cn

NYC-WTC_000436703

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000436703Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →