NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos air sampling results, Staten Island, Jul 2002

Machine-extracted title · confidence 42%

Laboratory report of asbestos air sample results from Staten Island sites, with TEM/PCM methods and fiber concentrations.

NYC-WTC_000436367
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

NYC Response Asbestos Air Sampling ResuSts for Staten island Landfiii Sampling Date and Time 7/15'20020700 to 2010 Date VaSidatioii Date; 07/19/2002

PCM by NiOSH 7400 ___________ TEM ( AHERA) Sampling Sampling Sample Structures (#) Date Sample No. Location Volume* Matrix f/mm^ f/cc O.Sp - 5p 5!^ S/mm" S~f/cc‘* 07/15/02 LF05735 P-1 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 07/15/02 LF05736 P-2 1278.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 07/15/02 LF05737 P-3 1260.00 Air <7.0 <0.002 0 0 <15.75 <0.0048 07/15/02 LF05738 P-4 1260.00 Air <7.0 <0.002 0 0 <15.75 <0.0048 07/15/02 LF05739 P-5 821.70 Air <7.0 <0.003 0 0 <9.84 <0.0046 07/15/02 LF05740 P-6 424.80 Air <7.0 <0.006 0 0 <7.87 <0.0071 07/15/02 LF05741 P-7 1072.80 Air <7.0 <0.003 0 0 <13.12 <0.0047 07/15/02 LF05742 P-8 1067.40 Air <7.0 <0.003 0 0 <13.12 <0.0047 07/15/02 LF05743 W-12A 589.05 Air <7.0 <0.005 0 0 <7.87 <0.0051 07/15/02 LF05744 W-12B 1260.00 Air <7.0 <0.002 0 0 <15.75 <0.0048 07/15/02 LF05745 T-15 1332.00 Air <7.0 <0.002 0 0 <15.75 <0.0046 07/15/02 LF05746 T-16 1080.00 Air <7.0 <0.002 0 0 <13.12 <0.0047 07/15/02 LF05747 0-17 1188.00 Air <7.0 <0.002 0 0 <13.12 <0.0043 07/15/02 LF05748 0-18 1166.18 Air <7.0 <0.002 0 0 <13.12 <0.0043 07/15/02 LF05749 0-19 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 07/15/02 LF05750 Lot Blank 0.00 Air <7.0 n/a NA<^> NA<=^> NA<=^> NA<=^> 07/15/02 LF05751 Trip Blank 0.00 Air <7.0 n/a NA(^> NA® NA(=^> NA®

Key; * Some sample volume (liters) are below recommended limit for the TEM method; volume is based on pump reading ** Structure (S) is roughly equivalent to fiber (f) *** Chrysotile **** Actinolite ““‘Amosite NA <’) - Not analyzed due to overloading of particulates NA - Not analyzed for TEM NA - Not analyzed due to wet filter n/a - Not applicable NR - Not requested NS - Sample not submitted R - Sample data rejected due to no sample volume NC - Sample not collected NS - Sample not submitted

NiOSH 7400: Fiber Analysis of Air samples via NIOSH 7400, Revision 3, issue 2, 8/15/94 O Asbestos Fiber Analysis by Transmission Eiectron Microscopy (TEM) ERA 40CFR Part 763 (AHERA) H Standard criteria: EPA 40CFR Part 763 (AHERA); 0,01 fiber/cc (PCM), 70 S/mm’, volume 1200 L, for 25 mm filter (TEM)

to s o o o I Ln o

to o to co w?

NYC-WTC_000436367

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000436367Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →