WTC Tremolite fiber monitoring, 2000

Machine-extracted title · confidence 41%

Coordination and monitoring for asbestos-related Tremolite fiber sampling.

NYC-WTC_000435232–000435267
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

EPA R8 Multimedia Asbestos Sampling: Libby,MT January 4, 2000

2. Identify the Decision

The decision to be made is whether analysis of potential source materials and/or transport media in and about the mine (e.g., mine waste, surface water) and in and about the community of Libby (e.g., yard soil, house dust, garden soil) can be reliably quantified using available techniques. If so, then source areas judged to be of potential concern may be removed at the discretion of the OSC. Alternatively, additional sampling and analysis of potential source material may be pursed as needed to identify impacted areas and to focus on sources of unacceptable asbestos levels in air.

3. Identify Inputs to the Decision

Asbestos Measurements in Environmental Media

Inputs to the decision will be the results of asbestos analyses of each medium using the best available technique(s), as follows:

Proposed Method Medium Sample Preparation Sample Analysis Collect bulk sample, place on slide PLM of bulk material Yard soil Garden soil Collect bulk sample, dry Visible reflective infrared Road soil spectroscopy Mine waste Bulk insulation Separate respirable dust fraction using TEM of respirable dust Superfund method, collect dust on filter, collapse filter, prepare TEM grids Indoor Dust Microvacuum into cassette, suspend dust in TEM water/alcohol, collect on filter, dry ash, prepare TEM grids Surface Water Collect bulk sample, filter, collapse filter, TEM prepare TEM grids

These methods have been selected because they are judged to be the most likely to yield results that will allow qualitative or quantitative evaluation of asbestos levels in environmental media. Note that several alternative methods are identified for soil and related bulk materials. At present, it is not known which of these will be the most appropriate. It is envisioned that all samples will be screened using visible infrared spectroscopy, since this method is very fast and inexpensive. If successful, the results of this method can be used to rank-order samples into “high”. “medium” and “low” concentration ranges. For quantitative assessment, it is envisioned that all samples will be analyzed by PLM, since this method is fast and relatively less expensive than the Superfund TEM method. This evaluation will begin with samples that are known or suspected to

10

CITY_21MC100_009479261

NYC-WTC_000435244

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000435244Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →