Stuyvesant High ambient air samples, July 2002

Machine-extracted title · confidence 31%

Ambient air sample results outside tents at Stuyvesant High School; lead monitoring data.

NYC-WTC_000434819
Page image
Scanned page image, NYC-WTC_000434819
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

FROM: LEMBERT, ALEX

TO: Orlan,Bernard

DATE: 07/31/2002 06:01:29 PM

SUBJECT: FW: Stuyvesant High School

Bernie:

On 7/17/02 and 7/24/02 ambient air samples were collected outside the tent enclosures in room # 911 ( 9th floor-7.17.02 ) and room # 403 ( 4th floor-7/24/02 ) and analyzed for lead via NIOSH method 7082.

Results: Room # 911 15.5 ug/m3 Room # 403 .16.7 ug/m3

This data was evaluated in conjunction with the personal (OSHA) monitoring being conducted at the same time on personel working within the tent enclosure(s).

Results; Inside tent Room # 911 <6.4 & <5.7 ug/m3 Inside tent Room # 403 <4.2 & 7.5 ug/m3

As the results of samples collected within the tents are significantly lower than the samples collected outside the tents, this would indicate that the tent enclosures are operating effectively .

CITY_21MC100_010560053

NYC-WTC_000434819

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000434819Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →