one wipe samples were analyzed for lead. Fourteen of the wipe samples taken
during inspections came back positive for lead ranging from 6.21 ug/WOcm^to
70ug/1 OOcm^ . Significant lead wipe sampling results were referred to the New
York City Department of Health and Mental Hygiene to address lead issues, as
they deem appropriate. In addition trace levels of cadmium, beryllium,
molybdenum, nickel and vanadium was found in various establishments as well
as metals that are ubiquitous to the environment such as copper and iron oxide.
With the work practices employed by cleanup workers, none of the above results
posed a significant risk to worker safety and health. Workers exhibited good
hygiene practices and wore gloves while cleaning. Air sampling conducted on
workers while cleaning the locations where the above wipe samples were taken,
confirmed work practices employed at the time of sampling were sufficient to
control airborne contaminant exposure to below the PEL.
OSHA also conducted noise dosimetry during eleven inspections to evaluate
potential noise exposure during HEPA vacuuming and other noise producing
cleaning activities. Noise evaluations were conducted for each contractor
performing cleaning operations at the site. No noise exposures exceeded
OSHA’s action level of 85dBA as an eight-hour time weighted average or 50% of
the allowable noise dose.
Copies of all OSHA sample results have been provided to each contractor and
the EPA. In addition, each contractor has been notified that these records
constitute exposure records under 29CFR 1910.1020 and that compliance with
that standard is mandatory.
Upon the completion of this project, complete OSHA sampling data will be made
available to the EPA in database format.
TECHNICAL ISSUES
OSHA has provided technical safety and health support and assistance
throughout this project. During inspection activities OSHA compliance officers
have frequently provided guidance and assistance to contractors on safety and
health issues about various topics including but not limited to safety and health
programs, personal protective equipment, hygiene, ladder safety, fall protection,
and electrical safety. In addition, OSHA has provided input into HVAC and
Exhaust system bid specifications aimed at improving the safety and health of
those processes. This input aided in the development of controls and work
practices incorporated into the WTC Indoor Dust Cleaning Program
AC/Ventilation System Cleaning Procedures. OSHA has also provided technical
assistance to a contractor at the request of an EPA On-Site Coordinator relating
to lead risk assessment for a major scope B job.