Lead-in-dust wipe sampling report, PS 89M, Feb 2002

Machine-extracted title · confidence 58%

Limited lead-in-dust wipe sampling report for PS 89M, Feb 2002.

NYC-WTC_000326303–000326305
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Scope of Work

ATG Associates, Inc, (ATC) was retained by New York City Board of Education (NYG- BOE) to collect dust wipe to be analyzed for lead content. At the request of New York City Department of Health (NYC-DOH) and the approval of NYC-BOE a dust wipe sample was collected from the windowsill of room #306 in conjunction with the laboratory results of the dust wipe samples collected on February 14*, 2002 where elevated levels of lead were detected.

The purposed of the dust wipe sampling is to determine if dust on the windowsill of room #306 contains lead.

ATC’s representative Mr. Yiannis Efstathiou visited P.S. 89M located at 201 Warren Street, New York, NY on February 25*, 2002. At the request of NYC-DGH, the approval of NYC-BOE and in accordance with HUD protocols a dust wipe sample was collected from the windowsill of room #306.

LEAD-IN-D UST SAMPLING

Lead-in-dust threshold levels The New York City Health Code, part 173.14 and the Federal Departments of Housing and Urban Development (HUD) and Environmental Protection Agency (EPA) have established acceptable lead-in-dust levels for re-occupancy after a lead abatement has occurred (commonly referred to as “final clearance” levels). As stated in the Code, final clearance after abatement has taken place is achieved when dust wipe samples indicate lead levels ’ below those listed below:

For windowsills: 250 pg/tf

Although the lead-in-dust sample collected at P.S. 89M was not collected in response to lead abatement, the same threshold is used since no other regulations or standards are applicable to this project. ,

Sampling Methodology ATC provided all laboratory analytical services in support of this limited inspection. ATC is certified by the New York State Department of Health’s Environmental Laboratory Accreditation Program to perfonn lead and related analyses of environmental samples (Laboratory ID Number: 10879). The laboratory utilizes the United States Environmental Protection Agency analysis method number SW846-7420 and the National Institute of Occupational Safety and Health method number 7082M.

The lead-in-dust sample was obtained by gently wiping a pre-measured surface area with non-alcohol moistened towelettes. ATC’s representative wore disposable gloves and care was taken to avoid contamination of the towelette and collection vial. Towelette was

P.S. 89M February 26, 2002

CITY_21MC100_001827633 NYC-WTC_000326304

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000326304Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →