lAYLOR EIMVIRONA/IENTAL GROUR INC.

Stuyvesant High School Chambers Street, New York, NY SCA Project #:M477-15217, LLW#: 29881

Elevator Shaft(s) Cleaning and Testing Protocol

1. Prior to any cleaning work being performed inside the elevator shaft, each set of elevator doors on every floor ( not being used to access the elevator car and/or shaft) shall be sealed with a loose diaphragm consisting of two layers of six- mil plastic sheeting sealed with tape.

2. A licensed elevator mechanic shall secure the elevator car at the highest elevation of the elevator shaft. The HVAC cleaning contractor shall clean the elevator pit area using wet methods and/or HEPA vacuum.

3. Linder the supervision of a licensed elevator mechanic, the HVAC cleaning contractor shall clean all accessible interior surfaces of the elevator shaft and accessible exterior surfaces of the elevator car using wet methods and/or HEPA vacuum.

4. A visual inspection of all cleaned surfaces will be conducted to ensure they no visible dust/debris remain.

5. At the conclusion of a successful visual inspection, all accessible interior surfaces of the elevator shaft will be sealed with a ciear-coat encapsulant.

6. The ceiling access hatch of the elevator car will be opened , and the car will ascend and descend the shaft a number of times. Two air samples will then be collected inside the elevator car to be analyzed for asbestos (TEM AHERA) and airborne lead (NIOSH 7082).

130A JERICHO TPKE.. FLORAL PARK. NY HOOI ■ PHONE (516) 358-2955 • FAX (516) 358-1780

CITY_21MC100_010241200

NYC-WTC_000431534

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000431534Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000429999

HVAC/elevator shaft cleaning procedures and visual inspection steps.

Similar indexed content

Compare copies and versions →