Airborne asbestos analysis by TEM, PS 89M

Machine-extracted title · confidence 56%

TEM analysis of airborne asbestos at PS 89M; AHERA methodology and results.

NYC-WTC_000431525–000431528
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document K

AIRBORNE ASBESTOS ANALYSIS BY TR.vNSM!SS!QN ELECTRON MICROSCOPY CLIENT: New York Environmental PROJECT: P S. 89M ATHENICA LABORATORY U) #: T02-01-002 DATE OF REPORT: 01/11/02 gnvwonmmah serviccs mc, ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS; 01/11/02 TaL (7U) FILTER TYPE: M CE. EFFECTIVE FILTER AREA (mm’): 385 Fax. (7IA) AVERAGE G.O. AREA (mm’): 0.009936

LABORATORY RESULTS

CLIENT LAB. ID LOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMPHIB. it it at) ANAL ANALY SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST YZED ZED (sfruct./cm’) AIR CONC. FILTER FOR FOR CHRYS. TYPE (mm^ (slruc./cm’) CONC. STRUCT. STRUCT. SPECIFY' (strJmm*) 0.5SS<5pm S2S.0|un A-1 T02-01- 6“ floor in stair 1818 5 0.0497 0.0043 <0.0043 <20.13 NA NA NA NA 002-004 #3 A-2 T02-01- 6“ floor in boiler 1818 5 0.0497 0.0043 <0.0043 <20.13 NA NA NA NA 002-005 room A-3 T02-01- 6“ floor elevator 1809 5 0.0497 0.0043 <0.0043 <20.13 NA NA NA NA 002-006 room A-4 T02-01- 6“" floor fan 1800 5 0.0497 0.0043 0.0043 20.13 0.0043 <0.0043 Chrys. NA 002-007 room A-5 T02-01- In room 506 1800 5 0.0497 0.0043 <0.0043 <20.13 NA NA NA NA 002-008 A-6 T02-01- 5“ floor hall, o/s 1809 5 0.0497 0.0043 <0.0043 <20.13 NA NA NA NA 002-009 room 507

ANALYST LABORATORY DIRECTOR

o LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955

Athenica Environmental Services Inc. (AES), is responsible only for information pertaining to samples taken by its employees. Air sampling cassettes will be stored for sixty (60) days. AES Inc., should be notified within this time frame for a true duplicate analysis. S If .AES Inc., did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client. Under these circumstances, the air concentration data is o o supplied solely for t6e convenience of the client. o The report relates only to items tested. This report must not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government. Test reports may not be reproduced I except in full and with prior approval of AES Inc. o The liability of Athenica Environmental Services Inc. with respect to the services charged, shall in no event e.xceed the amount of the invoice. o NO Ui 1 o o

NYC-WTC_000431525

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000431525Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →