00 o

00

AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY o o ATHENICA CLIENT: New York Environmental PROJECT: PS. 89M o I EtMRONMEMTA^SEiwicEstM:. LABORATORY ID #: T02-01-002 DATE OF REPORT: 01/11/02 o T«I.(7U) 784.7490 ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS: 01/11/02 f«. (718) 78^005 FILTER TYPE: M. C.E. EFFECTIVE FILTER AREA 385 CM : AVERAGE G.O. AREA 0.009936 I H LABORATORY RESULTS u

CLIENT EAB. ID LOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMPHIB. 00 ANAL ANALY SENSmV. ASBESTOS ASBESTOS CONC CONC. TYPE ASBEST YZED ZED (stract/cm’) AIKCONC. FILTER FOR FOR CHRYS. TYPE {mm’) (stracycm^ CONC. STRUCT. STRUCT. SPECTFY (str7mm’) 0.5<S<5pm S^.Ojim A-13 T02-O1- j 3'''* floor in stair 1818 5 0.0497 0.0043 <0.0043 <20.13 NA NA NA NA 002-016 #3 A-14 T024)l- 3"* floor hall o/s 1818 5 0.0497 0.0043 <0.0043 <20.13 NA NA NA NA 002-017 room 301 A-15 T024)l- 3"* floor in Gym 1809 5 0.0497 0.0043 <0.0043 <20.13 NA NA NA • NA 002-018 A-16 T02-01- 3"* floor han 0/s . 1809 5 0.0497 0.0043 <0.0043 <20.13 NA NA NA NA 002-019 Gym A-17 T02-01- 2“'floor hall o/s 1809 5 0.0497 0.0043 <0.0043 <20.13 NA NA NA NA 002-020 room 201 A-18 T02-01- In room 204 1809 5 . 0.0497 0.0043 <0.0043 <20.13 NA NA NA NA 002-021

A/ ANALYST LABORATORY DIRECTOR

LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955

Alhenica Environmental Services Inc. (AES), is responsible only for information pertaining to samples taken by its employees. Air sampling cassettes will be stored for sixty (60) days. AES Inc., should be notified within this time frame for a true duplicate analysis. If AES Inc., did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client. Under these circumstances, the air concentration data is supplied solely for t6e convenience of the client. The report relates only to items tested. This report must not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government. Test reports may not be reproduced except in foil and with prior approval of AES Inc. The liability of Athenica Environmental-Services Inc. with respect to the services charged, shall in no event exceed the amount of the invoice.

3

NYC-WTC_000418835

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000418835Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →