Air Monitoring Requirements
For
114 Liberty Street
New York City Department of Environmental Protection
Bureau of Environmental Compliance
Consultant - Air Monitoring Requirements
Background
A follow-up visit to 114 Liberty Street revealed dust accumulations present on surfaces within the interior of
the building. The interior cleaning is to be accomplished by a licensed asbestos abatement contractor.
Purpose
The consultant shall provide personnel experienced and certified in asbestos air monitoring to be on-site, full-time,
during work area preparation and cleaning phases of building interiors (12 stories approximately 55,000 square
feet in total). The air monitor(s) will observe the work, conduct air monitoring for analysis via Transmission
Electron Microscopy (TEM) and monitor that the cleanup of the building interiors is being performed consistent
with the project specifications and appropriate regulatory requirements. Work shall be performed 24 hours per
day, seven (7) days per week
Air Monitoring/Construction Inspection Services
Air monitoring by an independent third party consultant shall be conducted during all cleanup activities. The
air monitoring consultant shall provide individuals certified as project monitors and air sampling technicians to
perform daily air sampling and inspections from the commencement of the project through to final air clearance
sampling. The air monitoring consultant shall provide sufficient equipment and experienced personnel to monitor
work area preparation and cleaning phases of the building interiors.
Qualifications
Project Monitoring
The Project Monitors must possess valid NYS Asbestos Project Monitor certificates. Monitors
must have served as a third party project monitor on at least 25 asbestos abatement projects.
Project Monitor must have performed final clearance inspections on at least 25 asbestos abatement
projects.
Technicians
Air monitoring technicians must possess valid NYS Asbestos Project Sampling Technician
(APST) certificates. Technicians must have performed air sampling for at least 6 months.
Proof of qualifications must be presented upon request.