NYC-WTC_000429160
Independent air monitoring and construction inspection for asbestos cleanup at 114 Liberty Street interior.
5 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗Proposal for independent air monitoring during asbestos cleanup at 114 Liberty Street; on-site TEM analysis plan.
NYC-WTC_000428730–000428732OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Air Monitoring Pequirements For 114 Liberty Street
New York City Department of Environmental Protection Bureau of Environmental Compliance
Consultant - Air Monitoring Requirements
Background
A follow-up visit to 114 Liberty Street revealed dust accumulations present on surfaces within the interior of the building. The interior cleaning is to be accomplished by a licensed asbestos abatement contractor.
Purpose
The consultant shall provide personnel experienced and certified in asbestos air monitoring to be on-site, full-time, during work area preparation and cleaning phases of building interiors (12 stories approximately 55,000 square feet in total). The air monitor(s) will observe the work, conduct air monitoring for analysis via Transmission Electron Microscopy (TEM) and monitor that the cleanup of the building interiors is being performed consistent with the project specifications and appropriate regulatory requirements. Work shall be performed 24 hours per day, seven (7) days per week
Air Monitoring/Construction Inspection Services
Air monitoring by an independent third party consultant shall be conducted during all cleanup activities. The air monitoring consultant shall provide individuals certified as project monitors and air sampling technicians to perform daily air sampling and inspections from the commencement of the project through to final air clearance sampling. The air monitoring consultant shall provide sufficient equipment and experienced personnel to monitor work area preparation and cleaning phases of the building interiors.
Qualifications
Project Monitoring The Project Monitors must possess valid NYS Asbestos Project Monitor certificates. Monitors must have served as a third party project monitor on at least 25 asbestos abatement projects. Project Monitor must have performed final clearance inspections on at least 25 asbestos abatement projects.
Technicians Air monitoring technicians must possess valid NYS Asbestos Project Sampling Technician (APST) certificates. Technicians must have performed air sampling for at least 6 months.
Proof of qualifications must be presented upon request.
1 of 1
CITY_DEP_WORBY_CANNATA_SUBP_000117452
NYC-WTC_000428730
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000429160
Independent air monitoring and construction inspection for asbestos cleanup at 114 Liberty Street interior.
5 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000425472
Proposal/overview of air monitoring and construction inspection by a contractor for interior cleaning.
5 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000428060
Independent air monitoring and construction inspection for asbestos cleanup at 114 Liberty Street interior.
5 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000421534
DEP air monitoring/inspection contract for 114 Liberty Street cleanup and HVAC system oversight.
5 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000429196
Air monitoring/inspection services for 114 Liberty Street cleanup and regulatory compliance.
5 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000426153
DEP correspondence regarding air monitoring scope and needs for 125 Cedar Street project.
5 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000433708
NYC DEP document outlining requirements for independent consultants to provide full-time air monitoring during asbestos abatement at 114 Liberty Street.
5 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000449810
NYC DEP document outlining requirements for independent consultants to provide full-time air monitoring during asbestos abatement at 114 Liberty Street.
5 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000234592
NYC DEP document outlining requirements for independent consultants to provide full-time air monitoring during asbestos abatement at 114 Liberty Street.
5 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000430686
NYC DEP document outlining requirements for independent consultants to provide full-time air monitoring during asbestos abatement at 114 Liberty Street.
5 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000416630
Consultant plan for asbestos air monitoring and on-site duties.
5 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000416659
Air monitoring/inspection service form for asbestos-related cleaning at 125 Cedar Street.
5 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000425472
Proposal/overview of air monitoring and construction inspection by a contractor for interior cleaning.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000429160
Independent air monitoring and construction inspection for asbestos cleanup at 114 Liberty Street interior.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000428060
Independent air monitoring and construction inspection for asbestos cleanup at 114 Liberty Street interior.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000421534
DEP air monitoring/inspection contract for 114 Liberty Street cleanup and HVAC system oversight.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000433708
NYC DEP document outlining requirements for independent consultants to provide full-time air monitoring during asbestos abatement at 114 Liberty Street.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000449810
NYC DEP document outlining requirements for independent consultants to provide full-time air monitoring during asbestos abatement at 114 Liberty Street.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Independent air monitoring and construction inspection for asbestos cleanup at 114 Liberty Street interior.
Similar indexed content
Proposal/overview of air monitoring and construction inspection by a contractor for interior cleaning.
Similar indexed content
Independent air monitoring and construction inspection for asbestos cleanup at 114 Liberty Street interior.
Similar indexed content
NYC-WTC_000421534
DEP air monitoring/inspection contract for 114 Liberty Street cleanup and HVAC system oversight.
Similar indexed content
NYC-WTC_000429196
Air monitoring/inspection services for 114 Liberty Street cleanup and regulatory compliance.
Similar indexed content