Page image not rendered yet. The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Stuyvesant High School
Chambers Street, New York, NY
SCA Project #:M477-15217, LLW#: 29881
Scope of Work/Sampiing Protocol for Clean-Up of Unit Ventilator's
Contractor: Kiss Construction, Inc.
1. TDX is to disconnect and open external cover of Unit Ventilator's in classroom
2. Kiss Construction will construct tent (1 layer 6 mil poly) around all Unit
Ventilator's within classroom. Kiss will use HEPA vacuum as negative air
3. Lead Personal Air Monitoring (IWA)
When Kiss starts building tent in each classroom, calibrate personal pump with
lead cassette to 2 L/min and put on one worker. Write Workers Name, SS
Number, and Room Number on Chain of Custody.
Examp/e: IfK/ss are bu/7c//np tents /n four (4} c/assrooms^
Tay/or iv/// be samp/ing 4 (four} different workers, (one in
each ciassroom/tent}
Change cassette(s) on worker(s) every 4 (four) hours. 2 (two) samples per
worker per shift
(Minimum Volume - 200L) - (100 Min @ 2 L/Min)
(Maximum Volume - 1500L) - (750 Min @ 2 L/Min)
4. Lead Ambient (outside tent) Air Monitoring (OWA)
When Kiss start building tent in each classroom, calibrate high volume (AC)
pump to 2 L/Min with lead cassette, use stand (S' High) and position pump away
from tent inside classroom near entrance to corridor/hallway.
Collect 1 (one) sample for duration of shift ('8 hours)
(Same minimum/maximum volumes as for personals)
At conclusion of sampling, collect air-samples (check final flow rates): personals
and ambients (collect 10% or minimum of 2 field blanks per batch) and drop off
samples to lab (ATC) for 12 hour turnaround time (not 6 hour: wipes only)
iVOTE: For aii iead air sampies write filOSH Method 7082 on Chain of Custody
and 12 hour turnaround time in Comments Section.
5. Kiss will clean Unit Ventilator's within tent enclosure. Taylor will perform visual
inspection of Unit Ventilator's and interior of tent to ensure no-dust remains.
Page 1 of 2
CITY_21MC100_010218261
NYC-WTC_000430074
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000430074Source: NYC Law Department, mirrored locally