Arsenic? asbestos TEM report, University (Aruborne) 2001

Machine-extracted title · confidence 22%

Transmission Electron Microscope asbestos analysis report with laboratory details, Dec 2001.

NYC-WTC_000430024–000430030
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

1— ro AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MFCROSCOPY a CLIENT; NYC SCA PROJECT; K.S. of Leadership & Public Services N5 Q

ATHENICA LABORATORY ID #: TOl-12-046 DATE OF REPORT: 12/30 /01 O

EMvnflariaa&rTAt services inc. ANALYT. METHODOLOGY: ?\H£RA DATE OF ANALYSIS; 12/27/01 Tei Via) 784-7 FILTER TYPE: M.C.E. EFFECTIVE FILTER AREA (mm’); 385 tn f»x. PU) 785-<fa5 AVERAGE G.O. AREA (rom’); 0.009936 tn

' LABORATORY RESULTS

CLIENT L.AB. ID U3CATION lOLUME G.O,'s AREA A.NALYT. TOTAL TOTAL AIR AJR AS BEST, AMT mu. H U (H) AMAL AN.ALV SENSITIV. A.SnESTO.S A.SBESTOS CONC. coNe TYPE ASBEST VZED ZED (st me Ue m^ AIR CONC. FILTER FOK FOR Cl IRVS, TYPE (mni ) (sIriicJciii*) CO.NC. STRl.CT. STRUCT. sPECin (ilr.finin’) O.SSS<5|iiii S>5.0(im 11 Tul-12- 10''' Floor 1260 7 0.0696 0.0044 <0.0044 <14,38 - - NA - N.4 NA NA 046-1931 hallway upp elevator 12 TO 1-12- 10'*’ Floor in 1260 7 0.0696 0.0044 <0.0044 <14.38 NA NA NA NA 046-1932 room 1015 13 TOl-12- 9'*' Floor elevator 1260 7 0.0696 0.0044 <0.0044 <14,38 NA NA NA NA 046-193.3 in hulhvay 14 TOl-12- 9'*‘ Floor in room 1260 7 0 0696 0 0044 <0.0044 <14.38 NA NA NA NA 046-1934 #909 15 TOl-12- S"' Floor opp. 1260 7 0.0696 0.0044 <0,0044 <14.38 NA NA NA NA r- 046-1935 ele\ ator in i - Lill way

i-:

ANALY,ST LABORATORY DtRECTOR I' E. Dimitrakas Spiro Dongnris r i. LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955

Allicnica EiivKor,mental ScTvici's Inc. (fVi-S). ii risponsible only For infonnition (leruiiiing Io samples Uken by its employees. Air simipicng casseilcs will lie stored for si.cty (60) dry*. AES Inc., should be notified wiOiin litis lime frame for a trie doplieolc analysis. o ir.’VES Ine., did no! cendue! Oie sampling, the reported airborne conccntraliori was derived based oieiiifonnation provided by the clienL Under these cireumslances, the air concmirjiion data is H supplied solely for l6e convenience of Ibe client. K Ihe report relates only Io ilems tested This report must not be used Io claim product endorsemenl by NVLAT or any oilier agency of lite Ij.S. fiovenimciiL Test reports may nol be reproduced I eecepl in full and with prior approval of AES Inc. The liability of .AlJienica Environmental Services Inc. with reaped to the servieca charged, shall in no event e.vceed Die amount of the invoice.

o o o o I o o to co CO 3 s •i

NYC-WTC_000430026

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000430026Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →