Arsenic? asbestos TEM report, University (Aruborne) 2001

Machine-extracted title · confidence 22%

Transmission Electron Microscope asbestos analysis report with laboratory details, Dec 2001.

NYC-WTC_000430024–000430030
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Isa AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY t- o •s. CLIENT: NYC SCA PROJECT: H.S. of Leadership & Public Services M O

ATHENICA LABORATORY lU ft: TO 1-12-046 DATE OF REPORT: 12/30/01 O M EXfotRCUttienAL SERVICES lnc. ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS. 12/27/01 T«k (719) 764-7VM FILTER TYPE: M.C.E. EFFECTIVE FILTER AREA (mm-): 385 *• 1 PlB)7M-«Ja5 AVER-AGE G.O. AREA (mm’); 0.009936 /463o 13 ' LABORATORY RESULTS si CLIENT LAB. ID LOCATION VOLUME G.O.’s AREA A KAL Yr. TOTAL TOTAL AIR AIR ASDEST. ampiiib. (10 anal ANALV SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEKl YZED ZED (struct /cin > AIR CONC. FILTER FOR FOR CHRYS. TlTE {nun') (sliuc./cm’) CONC. SfRUCT. STRUCT. .SPECIFY (s(r./mm’) (l.5<S<5pm SiS.Oglii 16 TOl-12- 8* Fluor IB room- 1260- 7 (1.0696 - ().0l)-14 <0.00-14 <14.38 NA : - NA 046-1936 #815 17 TOl-12- 7'*'Floor opp. 1260 7 0.0696 0.0044 <0.0044 <14.38 NA NA N.A NA 046-1937 elevator in ! if halhniy l« TOl-12- Floor in room 1260 7 0.0696 0.0044 <0.0044 <14.38 NA NA NA NA 046-1938 #705 19 TOl-12- Floor opp. 1260 7 0.0696 0.0044 <0,0044 <14.38 NA NA NA NA 046-1939 elevator in liallway 20 TOl-12- ri* Floor in room 1260 7 0.0696 0.0044 <0.0044 <14.38 NA NA NA NA 046-1940 #613

ANALYST LABORATORY DIRECTOR E. Dinutiakas Spiro Dongaris

LAUORATORY CERTIFICATION NDAUJERS; NVLAP 101958, ELAP 10955

.Alhmica Eiu'ironmental Services Inc. (.AES), is rcs^ionsihlc only for inforrncliori pertaining lo samples Liken by ils emploYces. .Ai sampling casscHcs will be stored foe sirty (oO) days. ATS Inc., ihoulJ be notified ivitliui Ibis lilftc frame for a (rue duplicate anslysis. Si If AES Inc., did not conduclthc lampltng, Ihc reported atihnnie eoncentnlion wits derived bistd onitiTonnatiori provided by the olieot. Under these cocumstances, the air conccnltation data is H ’ K .supplied jolely lor l6c convenience of the client. I The report relates only In linns u-rteJ. This i eport must not be used to claim piodticl cndotientcnl by NVLAP or soy nUier agency of the U.S. CiovejTUncnl. Test reports may no! be repoduced 1.: except in full and with prior approval of AES Inc. -flic liability of Alhtnica Lnvtiotuneolal Services Inc. wilhiespictto llie services chitged, shall in no cscnl exceed the amount of the invoice. o o o o I o OO I o

CO ■ 4 i co UI I

NYC-WTC_000430027

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000430027Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →