NYC 9/11 Public Portal Document

AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY CLIENT: NYC SCA PROJECT: Economics HS, M LABORATORY ID #: TOl-12-046 DATE OF REPORT: 12/30 /01 ATHEN IC A ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS: 12/27/01 EMviRONMENTAu SERVICES INC. FILTER TYPE: M.C.E. EFFECTIVE FILTER AREA 385 Tel. (718) 784-7490 AVERAGE G.O. AREA (mm’): 0.009936 fax. (718) 784-4085 LABORATORY RESULTS

CLIENT LAB. ID LOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMPiiin. # (tt) ANAL ANALY SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST YZED ZED (struct/cm’) AIR CONC. FILTER FOR FOR CHRYS. TYPE (mm’) (struc./cm’) CONC. STRUCT. STRUCT. SPECIFY (str./mm’) 0.S^S<Stun S^.flpm II TOl-12- 10* Floor 1260 7 0.0696 0.0044 <0.0044 <14.38 NA NA NA NA 046-1931 hallway opp. elevator 12 TOl-12- 10“ Floor in 1260 7 0.0696 0.0044 <0.0044 <14.38 NA NA NA NA 046-1932 room #1015 13 TOl-12- 9* Floor elevator 1260 7 0.0696 0.0044 <0.0044 <14.38 NA NA NA NA 046-1933 in hallway 14 TOl-12- 9* Floor in room 1260 7 0.0696 0.0044 <0.0044 <14.38 NA NA NA NA 046-1934 #909 15 TOl-12- 8“ Floor opp. 1260 7 0.0696 0.0044 <0.0044 <14.38 NA NA NA NA 046-1935 elevator in hallway

ANALYST LABORATORY DIRECTOR E. Dimitrakas Spiro Dongaiis

LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955

Athenica Environmental Services Inc. (AES), is responsible only for information pertaining to samples taken by its employees. Air sampling cassettes will be stored for sixty (6C) days. AES Inc., should be notified within this time flame for a true duplicate analysis. n If AES Inc., did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client. Under these circumstances, the air concentration data is supplied solely for t6e convenience of the client. The report relates only to items tested. This report must not be used to claim product endorsement by NVLAP or any other agency of the U .S. aovemment. Test reports may not be reproduced except in full and with prior approval of AES Inc. S The liability of Athenica Enviromnental Services Inc. with respect to the services charged, shall in no event exceed the amount of the invoice. n

3

co r r. E... 1 L_J L..J i 1 r.. 1 E r.. ’’1 r; r 1 L Z E J ■ 3 E/J CE3 co

NYC-WTC_000266892

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000266892Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →