Airborne asbestos TEM analysis, Economics HS

Machine-extracted title · confidence 58%

TEM analysis of airborne asbestos for Economics HS; 01-14-02 report date, AHERA methodology.

NYC-WTC_000266874–000266877
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY CLIENT: NYC SCA PROJECT: Economics HS, M, 100 Trinity Place LABORATORY ID #: T02-01-003 DATE OF REPORT: 01/14/02 ATHENICA ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS: 01/11/02 EMMRONMEMrAL SERVICES IRC. TA (71S) 7a4-7-W0 FILTER TYPE: M C E. EFFECTIVE FILTER AREA 385 Fm. (718) 7SA-*0aS AVERAGE G.O. AREA (mm^): 0.009936

LABORATORY RESULTS

CLIENT LAB. ID LOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMFHIB. # (It) ANAL ANALY SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST YZED ZED (strncL/cm’) AIR CONC. FILTER FOR FOR CHRYS. TYPE (mm’) (struc./cm’) CONC. STRUCT. STRUCT. SPECIFY (sti./nm?) 0.5^S<5^in S^.0(un 7 T02-01- In 8“ fl.,hallway, 1350 6 0,0596 0.0048 <0.0048 <16.77 NA NA NA NA 003-034 opp. elevators 8 T02-01- Lunch room, 1350 6 0.0596 0.0048 <0.0048 <16.77 NA NA NA NA 003-035 center 9 T02-01- In 7® fl., 1350 6 0.0596 0.0048 <0.0048 <16.77 NA NA NA NA 003-036 hallway, opp., rm. 705 10 T02-01- In room#706 1350 6 0.0596 0.0048 <0.0048 <16.77 NA NA NA NA 003-037 11 T02-01- hl hallway, opp., 1350 6 0.0596 0.0048 <0.0048 <16.77 NA NA NA NA 003-038 nn#606 12 T02-01- In room#607 1350 6 0.0596 0.0048 0.0048 16.77 <0.0048 0.0048 Chrys. NA 003-039

ANALYST LABORATORY DIRECTOR E. Dimitrakas Spiro Dongaris

LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955

n Athenica Environmental Services Inc. (.AES), is responsible only for information pertaining to samples taken by its employees. Air sampling cassettes will be stored for sixty (50) days. AES Inc., should be notified within this time fi-ame for a true duplicate analysis. If AES Inc., did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client. Under these circumstances, tlie air concentration data is supplied solely for t6e convenience of the client. s The report relates only to items tested. This report must not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government Test reports may not be reproduced n except in full and with prior approval of AES Inc, The liability of Athenica Environmental Services Inc. with respect to the services charged, shall in no event exceed the amount of the invoice.

[SO 2 Ln CTS CJS its O

NYC-WTC_000266875

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000266875Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →