• 0 every 15 minutes, when site operations or locations change, or when unexpected conditions arise) using the Direct Reading Monitoring Report (Figure 1) or equivalent. Integrated Personal Air Monitoring Personal sampling and analysis will be performed in accordance with the OSHA industrial Hygiene Technical Manual, the National Institute for Occupational Safety and Health (NIOSH) Manual of Analytical Methods, or other acceptable industrial hygiene practices if approved by BECHTEL; with sampling data recorded using the Air Monitoring Data Sheet (Figure 2) or equivalent. Noise Monitoring ATC may be required to perform noise monitoring for operations, which may exceed an 8-hour time weighted average sound level of 85 dBA. Noise monitoring shall be performed in accordance with 29 CFR 1910.95 using a SLM or noise dosimeter as appropriate. Personal Exposure Monitoring When appropriate color indicating badges or other media may be used to provide direct exposure assessments. ATC will provide and other media which could provide workers with personal methods of determining exposure. ATC will maintain adequate supplies as requested by BECHTEL. Other Site Monitoring Other site monitoring may be necessary depending on the job task or site location of the work. ATC may be directed by BECHTEL to provide additional area monitoring necessary to adequately assess and minimize worker exposure. Area monitoring will include asbestos and lead monitoring, plus respirable crystalline silica dust in selected break and rest areas. Monitoring Frequency When monitoring a worker’s exposure for comparison to a published exposure limit value (e.g., OSHA PEL’S, ACGIH TLV’s) monitoring may need to be conducted continuously (if there is the potential for build-up of a dangerous atmosphere), or over a full eight hour (or longer) work shift. For extended work shifts, samples should be for the shift duration and adjusted to reflect .extended work duration. In cases where shortened work shifts are used, samples will reflect actual task time. For asbestos, samples will be collected for a maximum of 8 hours during the highest expected fiber exposure period, in order to avoid overloading filters. Sampling Analysis ATC will analyze samples in accordance with the WTC Sampling Analysis Matrix (Table 2) but may substitute equivalent methods or procedures with approval from BECHTEL. Only analytical laboratories accredited by the American Industrial Hygiene Association shall perform sample analysis. The laboratory analysis will include field blanks, as required by the individual method or laboratory. The laboratories shall be successful participants in the NIOSH Proficiency Analytical Testing program for the appropriate analytical category. Prior to sampling, the specific sampling and analytical method(s) should be discussed with the receiving laboratory to determine any special requirements or variations to established methods necessary to collect an acceptable sample (Note: this may be required for high dust loaded samples). Sample data sheets with chain-of-custody information must accompany all samples shipped. Samples shall be packaged accordingly: » Filter Cassettes - Filter cassettes should be mailed in a cardboard box and packed with paper. Avoid using packaging peanuts or other static producing materia! because the static charge will draw material away and off the filter surface. This is especially true for asbestos fiber

_0O0aB9fiL

CITY_21MC100_003077168

NYC-WTC_000429603

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000429603Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →