NYC-WTC_000290906
RFP header for health monitoring and sampling at WTC emergency site, Oct 2001.
21 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Additional pages for the WTC health monitoring and sampling RFP, city file reference.
NYC-WTC_000280660–000280674OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Personal sampling and analysis will be performed in accordance with the OSHA Industrial Hygiene Technical Manual, the National Institute for Occupational Safety and Health (NIOSH) Manual of Analytical Methods, or other acceptable industrial hygiene practices. Only analytical laboratories accredited by the American Industrial Hygiene Association shall perform sample analysis. The laboratory analysis will include field blanks, as required by the individual method or laboratory. The laboratory shall also be successful participants in the NIOSH Proficiency Analytical Testing program for the appropriate analytical category. Prior to sampling, the specific sampling and analytical method should be discussed with the receiving laboratory to determine any special requirements or variations to established methods necessary to collect an acceptable sample (note this may be required for high dust loaded samples). 7.1.1 Noise Monitoring Noise monitoring shall be conducted for operations, which may exceed an 8-hour time weighted average sound level of 85 dBA (Refer also to Section). Noise monitoring shall be performed in accordance with 29 CFR 1910.95 using a SLM or noise dosimeter as appropriate.
Heat stress monitoring shall be conducted as necessary to assist in determining and maintaining appropriate work/rest regimens.
Other Site Monitoring Other site monitoring may be necessary depending on the job task or site location of the work. The Contractor may be requested to provide additional area monitoring necessary to adequately assess and control worker exposure. Area monitoring will include asbestos and lead monitoring plus respirable and total dust in selected break and rest areas.
Sampling Quality Persons conducting site monitoring shall have adequate training and/or . experience commensurate with the type and complexity of the monitoring program. They should be able to understand the limitations of the equipment they use, proper methods of calibration, proper methods of sealing and shipping samples and the importance of chain-of-custody.
All instruments shall be calibrated or checked for proper function if appropriate before use for each shift. Instrument checks may be necessary during the day and at the end of use to confirin instrument accuracy. Duplicate readings may be taken to confirm individual instrument response. Air sampling pumps will be calibrated with primary standards (e.g., dry calibrator or bubble-tube method). Instruments shall be operated and maintained in accordance with the manufacturer’s specifications. The manufacturer’s operation and maintenance manual will be kept at. the site work location for each type of instrument that is being used.
Samples sent to a laboratory for analysis shall be packaged to prevent damage, spillage, or leaks. An air or bulk sample data sheet with chain-of-custody information must accompany any sample shipped.
4
CITY_21MC100_002948056
NYC-WTC_000280666
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000290906
RFP header for health monitoring and sampling at WTC emergency site, Oct 2001.
21 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000280647
Doc header for health monitoring and sampling RFP, 10/01/01, contract file.
15 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188121
Request for Proposal document from October 1, 2001, regarding health monitoring and sampling at the World Trade Center emergency site.
15 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317719
SOW describing general site exposure monitoring for WTC demolition/repair work.
13 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000267538
RFP for health monitoring and sampling at the WTC emergency site, 10/01/01.
16 shared non-person entities · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000386300
Chain of custody/health monitoring RFP document for WTC site, dated 10/01/01.
20 shared non-person entities · 1 shared topics · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149798
Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.
10 shared non-person entities · 1 shared topics · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000241781
Draft confidential sampling and exposure monitoring plan for WTC debris events.
8 shared non-person entities · similarity 0.960
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000232249
Program documentation for ambient air monitoring during the deconstruction project at 130 Liberty Street issued by LMDC in May 2005.
11 shared non-person entities · 1 shared topics · similarity 0.960
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000165900
Document page containing contact details for Con Edison and JWC Environmental Health & Safety personnel.
11 shared non-person entities · 1 shared topics · similarity 0.959
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000447726
Chain-of-custody and project header for ambient air monitoring at 130 Liberty Street Deconstruction, May 2005.
11 shared non-person entities · 1 shared topics · similarity 0.959
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155430
Technical correspondence addressing asbestos air sampling methodology and pump flow rate specifications.
8 shared non-person entities · 1 shared topics · similarity 0.959
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000290906
RFP header for health monitoring and sampling at WTC emergency site, Oct 2001.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317719
SOW describing general site exposure monitoring for WTC demolition/repair work.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000386300
Chain of custody/health monitoring RFP document for WTC site, dated 10/01/01.
Similarity score 0.974 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000280647
Doc header for health monitoring and sampling RFP, 10/01/01, contract file.
Similarity score 0.969 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188121
Request for Proposal document from October 1, 2001, regarding health monitoring and sampling at the World Trade Center emergency site.
Similarity score 0.967 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000454574
Specifications for asbestos-containing exterior sealants and caulking materials abatement.
Similarity score 0.967 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000290906
RFP header for health monitoring and sampling at WTC emergency site, Oct 2001.
Similar indexed content
SOW describing general site exposure monitoring for WTC demolition/repair work.
Similar indexed content
Doc header for health monitoring and sampling RFP, 10/01/01, contract file.
Similar indexed content
NYC-WTC_000267538
RFP for health monitoring and sampling at the WTC emergency site, 10/01/01.
Similar indexed content
Request for Proposal document from October 1, 2001, regarding health monitoring and sampling at the World Trade Center emergency site.
Similar indexed content