Personal sampling and analysis will be performed in accordance with the OSHA Industrial
Hygiene Technical Manual, the National Institute for Occupational Safety and Health (NIOSH)
Manual of Analytical Methods, or other acceptable industrial hygiene practices. Only analytical
laboratories accredited by the American Industrial Hygiene Association shall perform sample
analysis. The laboratory analysis will include field blanks, as required by the individual method
or laboratory. The laboratory shall also be successful participants in the NIOSH Proficiency
Analytical Testing program for the appropriate analytical category. Prior to sampling, the
specific sampling and analytical method should be discussed with the receiving laboratory to
determine any special requirements or variations to established methods necessary to collect an
acceptable sample (note this may be required for high dust loaded samples).
7.1.1 Noise Monitoring
Noise monitoring shall be conducted for operations, which may exceed an 8-hour time weighted
average sound level of 85 dBA (Refer also to Section). Noise monitoring shall be performed in
accordance with 29 CFR 1910.95 using a SLM or noise dosimeter as appropriate.
Heat stress monitoring shall be conducted as necessary to assist in determining and maintaining
appropriate work/rest regimens.
Other Site Monitoring
Other site monitoring may be necessary depending on the job task or site location of the work.
The Contractor may be requested to provide additional area monitoring necessary to adequately
assess and control worker exposure. Area monitoring will include asbestos and lead monitoring
plus respirable and total dust in selected break and rest areas.
Sampling Quality
Persons conducting site monitoring shall have. adequate training and/or . experience
icbmmfeiisurafe: with the type and complexity of the monitoring program. They should be able to
understand the Limitations of the equipment they use, proper methods of calibration, proper
methods of sealing and shipping samples and the importance of chain-of-custody.
All instruments shall be calibrated or checked for proper function if appropriate before use for
each shift. Instrument checks may be necessary during the day and at the end of use to
confirm instrument accuracy. Duplicate readings may be taken to confirm individual
instrument response. Air sampling pumps will be calibrated with primary standards (e.g., dry
calibrator or bubble-tube method). Instruments shall be operated and maintained in
accordance with the manufacturer’s specifications. The manufacturer’s operation and
maintenance manual will be kept at the site work location for each type of instrument tha.t is
being used.
Samples sent to a laboratory for analysis shall be packaged to prevent damage, spillage, or leaks.
An air or bulk sample data sheet with chain-of-custody information must accompany any sample
shipped.