NYC 9/11 Public Portal Document
10/01/01 MON 10:10 FAX 212 695 5984 Bechtel URS Greiner JV 0007
• Filter Cassettes - Filter cassettes should be mailed in a cardboard box and packed with paper.
Avoid using packaging peanuts or other static producing material because the static charge
will draw material away and off the filter surface. This is especially true for asbestos fiber
samples. Filter cassettes shall be taped over the top and bottom to keep the plugs on the end
of the cassette and to prevent sample tampering prior to analysis.
• Charcoal Tubes - Charcoal tubes should be mailed in a cardboard box and adequately
packaged to prevent breakage during shipment. Bulk solutions must never be shipped in the
same package as charcoal tubes.
• Bulk Samples - Bulk samples shall be packaged in labeled containers compatible with
the sample and tightly sealed to prevent leaks and spills. Keep in mind that some bulk
samples may be considered as hazardous materials by the Department of Transportation and
have special requirements for packaging, labeling, and method of shipment.
Data Review
The Contractor will assess and interpret monitoring data and results based on standard industry
practices and professional judgment. All calculations performed on raw data (e.g. time-
weighted-average calculations) shall be documented and reviewed by a Certified Industrial
Hygienist.
Additional Site Monitoring Requirements
Monitoring Frequency
Monitoring or sampling frequency will be influenced by a number of factors including the
following:
• frequency of contaminant release (i.e., continuously, intermittently, one time release)
• frequency of operation
• number of samples required
• number of different work groups requiring assessment
.,5;./number of work shifts requiring monitoring;;;; s.; , 4?i; .i;;..
Each of these factors should be considered to determine the monitoring frequency.
When monitoring a worker’s exposure for comparison to a published exposure limit value such
as the OSHA PEL’S or ACGH TLV’s, monitoring may need to be conducted over a full eight
hour (or longer) work shift or a 10 to 15 minute period of time. For extended work shifts,
samples should be for the shift duration and adjusted to reflect extended work duration. For
asbestos, samples will be collected for maximum 8 hours during the highest expected fiber
exposure, for a period of time in order to avoid overloading filters.
In some cases, monitoring may need to be continuous if there is the potential for build-up of a
dangerous atmosphere. Monitoring duration can also be affected by the duration of the operation
being monitored (i.e., it may only operate one hour a day) or by the length of time a worker
performs an operation. Duration can also be affected by the contaminant concentration in air.
Often times, higher concentrations of air contaminants will require the collection of shorter-term
samples so as to avoid overloading the sample collection device being used.
CITY_21MC100_002948042
NYC-WTC_000280652
OCR can misread numbers and units. Confirm readings against the page image before using them.