Scope of Work

2.1 Air Sampling Procedures

ALC’s licensed technicians collected air samples using the TEM Methodology

The air samples were collected using high volume air sampling pumps Once the pumps were in place, the air sampling technician recorded the location, time, date, sample numbers, pump number, flow rate, start and stop times and his initials

The air sampling cassette was independent of he pump motor This is to prevent the vibrauons of the motor from affecting the fibers in the cassette A separate stand or tnpod was used to hold the cassette in place The cassette was angled 45 degrees downward from the honzontal stand This IS to insure tliat no asbestos will drop into the cassette while sampling

Using a rotameter, we calibrated each pump tc the required flow rate, nottng this rate on the sample record. After calibrating the pumps, tlie end cap from the cassette was removed, the pump was then run for the required amount of Ume

The sampling pumps were checked penodical y to ensure they were still operating, the cassettes were still tn place, and no one had disturbed tlie equipment If at any time, the area being sampled was suspected of having high fiber counts, the filter inside the cassettes was examined for ‘overloading’’, or an excessive amount of fibers and/or debns on the filter

When the pre-determined volume of air was collected, the technician then calibrated the sampling pump again to determine the current flow rate This rate will often be different from the flow rate measured at the beginning of the sampling period That difference is usually due to the clogging of the filter, thereby adding increased resistance to the flow of air

Once the pre-determined volume of air was reached, the Ume was recorded on the chain of custody form as well as on the cassette. Before the pump was turned off, the cassette was angled upward and the cap replaced on the end plug. The cassettes were placed in sealed containers. labeled with an identifying code and a sample log was kept. The samples were then submined to the laboratory to be analyzed for asbestos content. A chain of custody record was completed and accompanied the samples to the laboratory.

2.2 Asbestos Analysis and Methodology

Each air sample is cross-referenced by field designation and lab internal code to ensure proper, consistent handling through a chain of custody. Sample preparation takes place within a HEPA Filter clean bench to avoid any possible contamination. Air sampling was conducted at a level approximating the breathing zone of persons anticipated to be present in the area dunng normal operations Samples collected represent the tvpical airborne fiber concentration of the area

3. Findings and Conclusions

One hundred and six (106) air samples were collected and analyzed via TEM Methodology, The results indicated that the areas achieved the acceptance criteria below <70 structures per mm2 set by the above regulauons.

CITY_DEP_WORBY_CANNATA_SUBP_000004118

NYC-WTC_000367308

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000367308Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000367337

Chain-of-custody accompanying TEM air sampling report for 100-600 buildings project.

Similar indexed content

Sampling and TEM report, Jan 2002

NYC-WTC_000367286

Chain-of-custody and TEM sampling events for [name] property; includes dates in December 2001.

Similar indexed content

NYC-WTC_000367356

Chain-of-custody accompanying TEM air sampling report for 375 Avenue building project.

Similar indexed content

Compare copies and versions →