NYC 9/11 Public Portal Document
Scope of Work
2.1 Air Sampling Procedures
ALC's licensed technicians collected air samples using the TEM Methodology
The air samples were collected using high volume air sampling pumps. Once the pumps were in
place. the air sampling technician recorded the location, time, date, sample numbers, pump
number, flow rate, start and stop times and his initials.
The air sampling cassette was independent of the pump motor. This is to prevent the -vibrations
of the motor from affecting the fibers in the cassette. A separate stand or tripod was used to hold
the cassette in place. The cassette was angled 45 degrees downward from the horizontal stand.
This is to insure that no asbestos will drop into the cassette while sampling.
Using a rotameter, we calibrated each pump to the required flow rate. noting this rate on the
sample record. After calibrating the pumps, the end cap from the cassette was removed: the
pump was then run for the required amount of time.
The sampling pumps were checked periodically to ensure they were still operating, the cassettes
were still in place, and no one had disturbed the equipment. If at any time, the area being
sampled was suspected of having high fiber counts. the filter inside the cassettes was examined
for `overloading", or an excessive amount of fibers and/or debris on the filter.
When the pre-determined volume of air was collected, the technician then calibrated the
sampling pump again to determine the current flow rate. This rate will often be different from
the flow rate measured at the beginning of the sampling period. That difference is usually due to
the clogging of the filter, thereby adding increased resistance to the flow of air.
Once the pre-determined volume of air was reached the time was recorded on the chain of
custody form as well as on the cassette. Before the pump was turned off, the cassette was angled
upward and the cap replaced on the end plug. The cassettes were placed in sealed containers,
labeled with an identifying code and a sample log was kept. The samples were then submitted to
the laboratory to be analyzed for asbestos content. A chain of custody record was completed and
accompanied the samples to the laboratory.
2.2 Asbestos Analysis and Methodology
Each air sample is cross-referenced by field designation and lab internal code to ensure proper,
consistent handling through a chain of custody. Sample preparation takes place within a HEPA
Filter clean bench to avoid any possible contamination. Air sampling was conducted at a level
approximating the breathing zone of persons anticipated to be present in the area during normal
operations. Samples collected represent the typical airborne fiber concentration of the area.
3. Findings and Conclusions
One hundred and one (101) air samples were collected and analyzed via TEM Methodology. The
results indicated that the areas achieved the acceptance criteria below <70 structures per mm2 set by the
above regulations.
NYC-WTC 000121184