4.2 Air Sampling Procedures
technician
ALC's licensed technicians collected air samples using TEM Methodology. The
collected five (5) air samples on each floor. The samples were taken in three (3) apartments and at
identified the locations that
g4` two separate areas in the hallways on each floor. The technician
appeared to contain the most visible dust and debris to perform sampling.
Once the pumps were in
The air samples were collected using high volume air sampling pumps.
technician recorded the location, time, date, sample numbers, pump number,
place the air sampling
flow rate, start and stop times and his initials.
prevent the vibrations of the motor
he air cassette was independent of the pump motor. This is to
or tripod was used to hold the cassette in
from affecting the fibers in the cassette. A separate stand
downward from the horizontal stand. This is to insure
place. The cassette was angled 45 degrees
that no asbestos will drop into the cassette while sampling.
rate, noting this rate on the
Using a rotameter, we calibrated each pump to the required flow
sample record. After calibrating the pumps, the end cap from the cassette was removed; the pump
was turned on and run for the required amount of time.
still operating, the cassettes
The sampling pumps were checked periodically to ensure they were
equipment. If at any time the area being sampled
were still in place, and no one has disturbed the
counts, the filter inside the cassettes were examined for
was suspected of having high fiber
`overloading", at an excessive amount of fibers and/or debris on the filter.
technician then calibrated the
When the pre-determined volume of air has been collected, the
often be different from the
sampling pump again to determine the current flow rate. This rate will
period. That difference is usually due to the
flow rate measured at the beginning of the sampling
clogging of the filter, thereby adding increased resistance to the flow of air.
was recorded as well as on the
Once the pre determined volume of air has been reached, the time
was turned off, the cassette was angled upward and the cap replaced
cassette. Before the pump
labeled with an identifying code
and the end plug. The cassettes were placed in sealed containers,
laboratory to be analyzed for
and a sample log was kept. The samples were then submitted to the
and accompanied the samples to the
asbestos content. A chain of custody record was prepared
laboratory.
43. Asbestos Analysis and Methodology
internal code to ensure proper,
Each air sample is cross-referenced by field designation and lab
consistent handling through a chain of custody. Sample preparation takes place within a HEPA
Filter clean bench to avoid any possible contamination. Air sampling was conducted at a level
approximating the breathing zone of persons anticipated to be present in the area during normal
represent the typical airborne fiber concentration of the area.
s operations. Samples collected
5. Findings and Conclusions
contrast microscopy (PCM)
Eight (8) initial background air samples were collected and analyzed via phase
at building 500. Four (4) samples were analyzed via Transmission Electron Microscopy (TEM). After
analysis via TEM all were below the permissible limits.
NYC-WTC 000117672