Chain-of-Custody: Air Sampling Report, 2002

Machine-extracted title · confidence 58%

Chain-of-custody accompanying TEM air sampling report for 375 Avenue building project.

NYC-WTC_000367356–000367358
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

2.1 Air Sampling Procedures

ALC’s licensed technicians collected an- samples using the TEM Methodology.

The air samples were collected using high volume air samplmg pumps. Once the pimps were in place, the air samplmg technician recorded the location, time, date, sample numbers, pump number, flow rate, start and stop times and his imtials.

The air sampling cassette was independent of the pump motor. This is to prevent the vibrations of the motor from affecting the fibers in the cassette. A separate stand or tripod was used to hold the cassette m place. The cassette was angled 45 degrees downward fi-om the horizontal stand. This is to insure that no asbestos will drop mto the cassette while samplmg.

Using a rotameter, we calibrated each pump to the required flow rate, noting this rate on the sample record. After calibrating the pumps, the end cap from the cassette was removed; the pump was then run for the required amount of time.

The sampling pumps were checked periodically to ensure they were still operating, the cassettes were still in place, and no one had disturbed the equipment. If at any time, the area bemg sampled was suspected of having high fiber counts, the filter inside the cassettes was examined for “overloadmg”, or an excessive amount of fibers and/or debris on the filter.

When the pre-determined volume of air was collected, the technician then calibrated the sampling pump again to determme the current flow rate. This rate will often be different from the flow rate measured at the beginmng of the sampling period. That difference is usually due to the clogging of the filter, thereby addmg mcreased resistance to the flow of air.

Once the pre-determmed volume of air was reached, the time was recorded on the cham of custody form as well as on the cassette. Before the pump was turned off, the cassette was angled upward and the cap replaced on the end plug The cassettes were placed m sealed contamers, labeled with an identifying code and a sample log was kept The samples were then submitted to the laboratory to be analyzed for asbestos content. A chain of custody record was completed and accompamed the samples to the laboratory.

2.2 Asbestos Analysis and Methodology

Each air sample is cross-referenced by field designation and lab internal code to ensure proper, consistent handling through a chain of custody Sample preparation takes place within a HEPA Filter clean bench to avoid any possible contamination Air sampling was conducted at a level approximating the breathing zone of persons anticipated to be present m the area during normal operations Samples collected represent the typical airborne fiber concentration of the area

3. Findings and Conclusions

One hundred and one (101) air samples were collected and analyzed via TEM Methodology. The results indicated that the areas achieved the acceptance entena below <70 structures per mm2 set by the above regulations

CITY_DEP_WORBY_CANNATA_SUBP_000002927

NYC-WTC_000367357

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000367357Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000367337

Chain-of-custody accompanying TEM air sampling report for 100-600 buildings project.

Similar indexed content

Sampling and TEM report, Jan 2002

NYC-WTC_000367286

Chain-of-custody and TEM sampling events for [name] property; includes dates in December 2001.

Similar indexed content

Compare copies and versions →